Evolve LRM-AS Series 300, Rel. 5.1 Instructions  
LRM-AS
by Evolve Guest Controls
bottom of the switch will dim the load.  When OFF, pressing and holding the bottom of the switch will 
cause the load will go to the minimum dim level. 
Note:  Upon restoration of power after a power loss, the LRM-AS returns to previous known state.     
LED indication
The LED on the LRM-AS will turn ON when the load attached is OFF, to act as a night light.  However, the LED 
can be user configured to turn ON when the load attached is ON, if so desired.
Remote Control
The LRM-AS will respond to bASIC and MULTILEvEL commands that are part of the Z-Wave system. Refer to 
your controller’s instructions as to whether your controller can transmit those commands.
All On/All Off
The LRM-AS supports the ALL ON/ ALL OFF commands.
The LRM-AS can be set to respond to ALL ON and ALL OFF commands 4 different ways.
Refer to your controller for information on how to set the LRM-AS to operate in the manner you desire. Some 
controllers may be only able to set certain settings of ALL ON/ALL OFF response.
The 4 different ways the LRM-AS can be setup to respond to ALL ON and ALL OFF commands are:
•  
LRM-AS will not respond to ALL ON or the ALL OFF command.
•  
LRM-AS will respond to ALL OFF command but will not respond to ALL ON command.
•  
LRM-AS will respond to ALL ON command but will not respond to ALL OFF command.
•  
LRM-AS will respond to ALL ON and the ALL OFF command (default).
Configuration
The LRM-AS supports the Configuration command.
The LRM-AS can be configured to operate differently than how it works when you first install it. Using the 
Configuration command you can configure the following: 
You can use a EHC-100 to send Configuration commands. (Refer to the Setup Menu, Configuration section)
 
night Light
by default, the LED on the LRM-AS will turn OFF when the load attached is turned ON. To make the LED 
turn ON when the load attached is turned ON, set parameter 3 to a value of 0.
•   parameter No: 3
•   Length: 1 Byte
•   Valid Values = 0 or 1 (default 1)
invert Switch
To change the top of the switch to OFF and the bottom of the switch to ON, set parameter 4 to 1.
•   parameter No: 4
•   Length: 1 Byte
•   Valid Values = 0 or 1 (default 0)
Load Sense:
•  parameter No: 29
•  Length: 1 Byte
•  Valid Values  = 0 or 1 (default 1)
Set this parameter to 0 to disable load sense. Set this parameter to 1 to enable load sense.
Each Configuration Parameter can be set to its default setting by setting the default bit in the Configuration Set 
command. See your controller’s instructions on how to do this (and if it supports it).
All Configuration commands will be reset to their default state when the LRM-AS is excluded from the Z-Wave 
network by using the controller to reset the node (on the EHC-100 select “SETUP” and scroll to “RESET UNIT”).