Справочник Пользователя для Huawei Technologies Co. Ltd RRU3260

Скачать
Страница из 135
Figure 7-5 Incorrect binding method
 
3.
Installation engineer B pulls the lifting sling downwards, and installation engineer C pulls
the traction sling outwards to protect the RRU from colliding with the tower.
Step 2 Installation engineer A catches the RRU, install the RRU on the main bracket, use an inner
hexagon screwdriver to tighten the captive screw into the hole of the attachment plate to 5 N·m
(44.25 lbf·in.) for connecting the attachment plate and the main bracket, see 
.
Step 3 Remove the lifting sling and traction sling.
NOTE
The procedure for hoisting the RRU and mounting kits onto the tower is for your reference only.
----End
7.2 Hoisting Fiber Optic Cables onto a Tower
This section describes the procedure for hoisting fiber optic cables onto a tower and the
precautions that must be taken.
Context
Procedure
Step 1 Hoist the fiber optic cables onto the tower, as shown in 
.
RRU3260
Installation Guide
7 Hoisting an RRU and Related Cables onto a Tower
Issue ()
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
46