Either before or after the Signpost is installed, the installer should 
set and verify the following settings for operation. This activity is 
performed using a computer having the Signpost configuration 
software application installed.
Before verifying these settings, you need to connect the computer 
to the Signpost, which is documented in “Connecting Signposts to a 
Computer” on page 3-2.
»
To verify the operation settings:
The following Signpost configuration application parameters need 
to be verified.
1. Configure the Signpost ID (1 to 65535)
The Signpost ID should be a unique number in the facility. 
The Signpost can be identified in the system by associating this 
number with a description in the Site Manager configuration.
2. Transmit group number (0 to 10)
The Transmit group number is used when a number of Signposts 
are transmitting at the same time or a different time. The factory 
setting is 0. The Signpost will not synchronize when the group 
number is 0. When you program a number from 1 to 10, Signposts 
having the same group number will transmit simultaneously. 
Otherwise, they transmit at a different time. 
3. Beacon Control on/off
The Beacon Control on/off option is used to program the tag 
whenever changing the beacon mode of the tag is required. 
When this option is disabled, the tag remains in the same mode. 
When the option is enabled, the tag beacon mode will be changed 
according to the command.