Справочник Пользователя для AeroComm Corporation 2510100

Скачать
Страница из 34
1 5
LT2510 User’s Manual
C O N F I G U R I N G   T H E   LT 2 5 1 0
LAIRD TECHNOLOGIES www.lairdtech.com
C O M M A N D   D E S C R I P T I O N S
Advanced Networking Commands
Bin Analyzer
<0xCC> <0x8F> <Data>
<0xCC> <0x8F>
E n t e r   A T   C o m ma n d   M o d e
Prior to sending this command, the OEM Host must ensure that the
transceiver’s RF transmit buffer is empty.   This can be accomplished by
waiting up to one second between the last packet and the AT command. If
the buffer is not empty, the radio will interpret the command as data and it
will be sent over the RF. 
Command: <0x41> <0x54> <0x2B> <0x2B> <0x2B> <0x0D>
Number of Bytes Returned: 4
Response: <0xCC> <0x43> <0x4F> <0x4D>
E x i t   A T  C o m m a n d   M o d e
The OEM Host should send this command to exit AT Command mode and
resume normal operation.
Command: <0xCC> <0x41> <0x54> <0x4F> <0x0D>
Number of Bytes Returned: 4
Response: <0xCC> <0x44> <0x41> <0x54>
E n t e r   D e e p   S l e e p
The OEM Host issues this command to put the module into a Deep Sleep
state to minimize current draw. In this state a Server will not send out a
beacon, a Client will not remain In Range and no commands sent over the
Serial UART will be processed.   To awake from Deep Sleep the OEM must
toggle the Up_Reset pin.
Command: <0xCC> <0x86> <0x03>
Number of Bytes Returned: None
Response: None
R e s e t
The OEM Host issues this command to perform a soft reset of the
transceiver. Any transceiver settings modified by CC commands will revert
to the values stored in the EEPROM.
Command: <0xCC> <0xFF>
Number of Bytes Returned: None
Response: None
S t a t u s   V e r s i o n  R e q u e s t
The OEM Host issues this command to request the firmware and link status
of the transceiver.
Command: <0xCC> <0x00> <0x00>
Number of bytes returned: 3
Response: <0xCC> <Firmware Version> <Status>
Parameter Range:
<Firmware>
=
Radio Firmware version
<Status>
=
0x02: Server 
0x03: Clients In Range
0x01: Client not In Range
R e a d   T e m p e r a t u r e
Ta b l e   7 :   C o m m a n d   Q u i c k   R e f e r e n c e
Command Name
Command (All bytes in Hex)
Return (All bytes in Hex)