4. PINOUT
MO2XX
MO190
Required
operation for
electrical
compatibility
IO type
Function
MO2XX
Description
Pin N°
XS2xx
Pin N°
MO190
Or
MO2xx
DAIRST
DAIRST
Not
required
Input
DAI reset
M4
116
DAIOUT
DAIOUT
Not
required
Output
DAI output data
M3
115
DAIIN
DAIIN
Not
required
Input
DAI input data
M2
   117
DAICLK
DAICLK
Not
required
Input
DAI
interface
(for
certification
tests only)
DAI clock
L2
118
USL1
Input
-
T5
USL2
Output
-
S4
USL3
Output
-
S5
USL4
Output
-
S6
USL5
Output
R3
USL6 (IO3)
Output
-
R4
USL7
Input
-
O17
USL8
Input
-
P17
USL9
Input
-
P16
USL10
Input
Useless
-
Q17
MOD_ESCAPE*_CMD MOD_ESCAPE*_CMD
Not
required
Input
Command mode
request signal (from
DTE to MO2XX)
interrupt
L14
18
USL11
Input
-
M15
USL12
Output
Useless
-
M14
DTE_ESCAPE_CMD
DTE_ESCAPE_CMD
Not
required
Output
Command mode
request signal (from
MO2XX to DTE)
L13
23
MOD_RESET_STATE
MOD_RESET_STATE
Not
required
Output
Signal showing a
RESET occurrence
of the module
M13
24
MOD_UART_STATE
MOD_UART_STATE
Not
required
Output
Signal giving the
state of the serial
link in the module
M12
25
MOD_FLOW_STATE
MOD_FLOW_STATE
Not
required
Output
Signal giving the
state of the module
M16
26
MOD_ON_STATE
MOD_ON_STATE
Not
required
Output
Signal giving the
state of the module
L15
27
MOD_ON*_CMD
MOD_ON*_CMD
Not
required
Input
ON signal
Module ON signal
B10
113
SIMVCC
SIMVCC
Not
required
Output
SIM power supply
T7
6
SIMRST
SIMRST
Not
required
Output
SIM
interface
SIM reset
T8