Справочник Пользователя для Symbol Technologies RF1224

Скачать
Страница из 2
LEDs / Ports
© 2006 SY
MBOL TECHNOLOGIES, INC. All rights reserved.
Symbol reserves the right to make changes to any product to improve reliability
, functio
n, or de
sign.
Symbol does not assume any product liability arising out of, or in connection with, the application or use of any product, circ
uit, 
or application described herein.
No license is granted, either expressly or by implication, estoppel, or otherwise under any patent right or patent, covering or
 
relating to any 
combination, 
system, apparatus, 
mac
hine, material, method, or 
process in which Symbol products might 
be used. 
An implied license exists only for equipment, circuits, and subsystems contained in Symbol products.
Symbol and the Symbol logo are registered trademarks of Symbol T
echnologies, Inc. Other product names mentioned in this 
manual may be trademarks or registered trademarks of their respective companies and are hereby acknowledged.
Symbol Technologies, Inc.
One Symbol Plaza
Holtsville, N.Y . 11742-1300
http://www.symbol.com
Referenc
e Document
s
Supporting documents, including the latest version of this guide are available for viewing/downloa
d from the Symbol 
documentation web site: 
http://www.symbol.com/manuals
Software updates, SDKs, development support and related documents are available from the Symbol Devzone web site:
http://devzone.symbol.com
Paten
ts
This product is covered by one or more of the patents listed on the web site: 
.symbol.com/patents
Wa
rranty
For the complete Symbol hardware product warranty statement, go to: 
http://www.symbol.com/warranty
 
Service Information
Contact information is provided on the Symbol contact web site:
 
LED / Ports
Description
Battery LED
Green - Bat
tery charge is good    
Flash Red - Battery needs charging.
Amber Flash - Battery is charging     
Solid Amber - Battery is
 fully charged
Error LED
Flash Red - Error
, replace unit.
External Antenna Port
RF1000-FL - Sup
ports up to one external antenna.
USB Client Port
USB client c
onnection.
External Power Port
See Power Supply
 for the Symbol approved power supply information. 
USB Client 
Port
External Power P
ort
External Antenna 
Port
Mountin
g Holes
 (4
)
Battery Do
or
Power Button
Error LED
Physica
l Co
nnecti
ons
Battery LED
72-XXXXX-01
Revision A — July 2006
RF1000-FL
Quick Reference Quide
Microsoft
®
 CE.NET
 5.0
Introduction
This Quick Reference Guide (QRG) provides the required information for all product models in the RF1XXX Series of RFID readers. 
The user documents use the RF1000-FL model number to generically reference all of the RFID readers in the series. 
The QRG includes LED definitions, port descriptions, and mounting information. For details, refer to the RF1000-FL Integrator 
Guide P/N 72E-XXXXX-XX
, available at: 
http://www.symbol.com/manuals
Product Description
The RF1000-FL is an intelligent, multi-protocol UHF RFID reader with RFID read performance that provides real-time, seamless 
EPC-compliant tags processing.
Features:
UHF Generation 2 support 
EPC Class 0 and Class 1
Intel XScale
®
 processor with Windows
®
 CE 
Support for custom or third-party applications
Feature set for event and tag management.
Firmware Updates
The RF1000-FL is shipped with the current firmware version. To install the latest upgrade refer to the RF1000-FL Integrator Guide 
P/N 72E-XXXXX-XX
, available from: 
http://www.symbol.com/manuals
Installation/Mounting
For details on the required procedures and detailed installation instructions refer to the RF1000-FL Integrator Guide P/N 72E-
XXXXX-XX
, available from: 
http://www.symbol.com/manuals
Prior to installation/mounting the following procedures must be performed:
The mounting brackets (or mounting platform) must be secured.
The LAN administrator must configure the RF1000-FL to communicate with the local LAN network and must set 
up the application interface software for the local LAN environment.
The battery must be fully charged. 
Mounting
1.
Insert the rubber shock mounts into the mounting holes.
2.
Position the RF1000-FL on the mounting brackets (or mounting platform). Ensure the clearance on all sides. 
3.
Insert the mounting bolts through the rubber shock mounts and through the bracket holes. 
4.
Attach the nuts onto the mounting bolts and tighten to 2.8 ft.-lbs to secure the RF1000-FL to the mounting brackets.
Operation
Press power button to toggle power on/off. The battery LED lights green to indicate the battery is good. If the Error LED flashes 
red, remove the unit and return to the network administrator.
Regulatory Information
All Symbol devices are designed to be compliant with rules and regulations in locations they are sold and will be labeled as 
required. 
If local language translations are available, they are provided at: http://www.symbol.com/services/manuals.
Any changes or modifications to Symbol Technologies equipment, not expressly approved by Symbol Technologies, could void 
the user's authority to operate the equipment.
Antennas: Use only the supplied or an approved replacement antenna. Unauthorized antennas, modifications, or attachments 
could cause damage and may violate regulations
Caution: Only use Symbol approved and UL Listed accessories, battery packs and battery chargers.
 
Do NOT attempt to charge damp/wet units or batteries. All components must be dry before connecting to an external 
power source.
Products Equipped with Bluetooth® Wireless Technology
This device can contain the following Bluetooth® qualified subsystems:
• BTID: B01825
• BTID: B02413.
Country Approvals 
Regulatory markings are applied to the device signifying country approvals, see notes 1 and 2
Please refer to the Symbol Declaration of Conformity (DoC) for details. This is available at http://www2.symbol.com/doc/.
Note 1: The use of 5GHz RLAN's have varying restrictions of use; please refer to the Symbol Declaration of Conformity (DoC) for 
details.
Note 2: The use of RFID Devices have varying restrictions of use; please refer to the Symbol Declaration of Conformity (DoC) for 
details.
Operation of the device without regulatory approval is illegal.
Health and Safety Recommendations
Warning for Use of Wireless Devices
Please observe all warning notices with regard to the usage of wireless devices.
Potentially Hazardous Atmospheres
You are reminded of the need to observe restrictions on the use of radio devices in fuel depots, chemical plants etc. and areas 
where the air contains chemicals or particles (such as grain, dust, or metal powders) and any other area where you would 
normally be advised to turn off your vehicle engine. 
Hearing Aids
The wireless device may interfere with some hearing aids. In the event of interference you may want to consult your hearing aid 
supplier to discuss solutions.
Other Medical Devices
Please consult your physician or the manufacturer of the medical device, to determine if the operation of your wireless product 
may interfere with the medical device.
FCC / EU RF Exposure Guidelines
Safety Information
Reducing RF Exposure - Use Properly
It is advisable to use the device only in the normal operating position.
The device complies with Internationally recognized standards covering Specific Absorption Rate (SAR) related to human 
exposure to electromagnetic fields from radio devices.
Remote and Standalone Antenna Configurations.
To satisfy FCC RF exposure requirements, a mobile transmitting device must operate with a minimum separation distance of 
25cm
 or more from a person's body.
Power Supply
Use only a Symbol approved power supply output rated 12 Vdc and minimum 3.33 A. The power supply is certified to EN60950-1 
with SELV outputs. Use of alternative power supply will invalidate any approval given to this device and may be dangerous.
Batteries
Please follow the local regulations when disposing of re-chargeable batteries.