Справочник Пользователя для Inovonics Wireless Corporation 3B6OT9U1X
© Inovonics, 2011 - www.inovonics.com
EN1262 EchoStream® Passive Infrared Motion
Detector
Detector
Installation and Operation Manual - 05469C
1 Overview
The EN1262 is a low-current motion detector highly sensitive to moving
heat (infrared radiation) sources.
heat (infrared radiation) sources.
1.1 Inovonics Contact Information
If you have any problems with this procedure, contact Inovonics technical
services:
services:
• E-mail: support@inovonics.com
• Phone: (800) 782-2709; (303) 939-9336
• Phone: (800) 782-2709; (303) 939-9336
2 Installation and Startup
2.1 Mount the Housing
1. Insert a small flat-blade screwdriver at the tab on the bottom of the unit.
The screwdriver will enter the slot at about a 45° angle. Press
downward on the handle of the screwdriver until the latch holding the
cover to the housing base releases.
downward on the handle of the screwdriver until the latch holding the
cover to the housing base releases.
Figure 1 Open the housing
2. Pull the circuit board attachment latch and lift the circuit board out of the
2. Pull the circuit board attachment latch and lift the circuit board out of the
housing.
Figure 2 Circuit board attachment latch
3. Wall tamper installation is required for BSI Class VI.
3. Wall tamper installation is required for BSI Class VI.
a. Use a 3/16” (4.8mm) bit to drill out the tamper rivet hole index.
b. Install the tamper wall anchor.
b. Install the tamper wall anchor.
Figure 3 Mounting hole indices
4. Mount the housing, using either the three wall-mount holes, or the four
corner-mount holes.
a. Use a 5/32” (4 mm) bit to drill out the appropriate housing hole
indexes.
b. Use the included screws to mount the housing.
indexes.
b. Use the included screws to mount the housing.
5. If using the wall tamper, ensure the wall tamper rivet depresses the wall
tamper switch arm.
Figure 4 Wall tamper switch
2.1 Set Parameters
1. If using the wall tamper, remove the shunt from the wall tamper
selection pins.
Figure 5 EN1262 Components
Circuit board
attachment
latch
attachment
latch
A Taper rivet index
B Corner mount index
C Wall mount index
A Wall tamper
selection pins
B Housing tamper
switch
C Frequency band
selection pin
D Reset button
A
B
B
B
B
C
B
B
C
C
Wall tamper
rivet
rivet
Wall tamper
switch arm
switch arm
C
A
B
D