Apartment Control Panel Requirements                Confidential 
Page 3
 10/12/2006 
1.1 Product Specifications 
The Apartment Control Panel contains the following overall features: 
-  Self contained security system with two line LCD text display 
-  System will contain provision for wired and wireless zones, 4 wired zones 
plus up to sixteen wireless zones 
-  Wall Mount or Table top installation  
-  Contains 433 MHz wireless receiver plus IWC Train 900 MHz transceiver 
-  Supports up to 16 433MHz based wireless sensors and up to 6 wireless 
keyfobs 
-  Keypad and remote programmable 
-  Communicates through Inovonics EchoStream Infrastructure to Master 
Communications Controller (MCC) 
-  Line powered unit (plug in transformer) with built in battery back-up 
-  Contains built in alarm sounder with min.90 dB output 
-  User Codes – Six homeowner codes, Installer code, Maintenance code 
-  Transmits CS messages to MCC for transmission to CS over telephone line in 
CID format 
-  Event log – time stamped with 99 events 
-  Chime mode – single button operation 
-  Single Button Arming modes available 
 
 
 
1.2 Part Numbers 
 
Inovonics will provide the stocking part numbers for each of the products prior to 
the initial shipments 
 
1.3 Documentation 
 
Inovonics will create Installation Instructions and an End Users manual for the 
Security System. This documentation will be included with each unit. 
  
1.4 Packaging 
 
Inovonics will define the packaging requirements for all products prior to the 
initial shipments. 
 
 
1.5 Regulatory Requirements 
 
The Security System must be designed and listed for the following regulatory 
standards: 
  FCC 
Part 
15 
 
 
UL 1023 Household Burglary Alarm System 
 
 
UL 1635 Digital Alarm Communicator System