Справочник Пользователя для Honeywell International Inc. CX85WCR

Скачать
Страница из 80
Part Replacement Procedures 
6-23 
DIAD 6 Charge Rack Manual 
 
 
 
 
Power Distribution - Board 50142378-001FRE 
 
 
Power Distribution - Board 50142378-001FRE 
 
 
Part Name: 
 
Power Distribution Board 
 
 
 
 
Part #: 
 
50142378-001FRE 
 
Tools Required: 
 
1 medium #2 Phillips head 
screw driver 
 
 
 
 
   
Before working on the Charge Rack, always disconnect the AC cord from the power 
supply. 
   
After removing power, wait 15 minutes before servicing the unit to avoid shock. 
Isolate screws by size as you remove them to ensure proper placement when reinstalling. 
 
1.  Remove the 6-slot bay from the Charge Rack. 
2.  Disconnect the 6 cables from the I/O board. 
3.  Remove the two screws between the power board and the 6-slot bay. 
 
 
 
4.  Separate the power board from the bay. 
5.  Replace the broken board with the new one.