Chapter 5
Operating
2100.4400.32
- 5.58 -
E-2
5.3.1
Automatic Input Switchover
The transmitter has an automatic switchover function which, in the event of a signal failure,
switches the transmitter from one input to the other input (provided that a valid input signal
is available at the standby input). Before a failure occurs, the preselected input is active.
The way in which this automatic switchover function operates is determined by the following
factors:
– Automatic switchover: ON or OFF (Autoswitch)
– Delay times which must elapse before the switchover is performed (Check Time For-
ward and Check Time Back)
– Priority mode: Inputs have the same priority or the preselected inputs have priority (Pri-
ority)
– Operating and standby inputs synchronized or not synchronized (in conjunction with
Seamless Switching)
Note
Automatic input switchover is not available with hierarchical coding.
Automatic input switchover ON/OFF
If automatic switchover is OFF, the preselected input remains active even if the input signal
fails.
If automatic switchover is ON and there is a failure at the preselected input, switchover to
the associated standby input takes place.
Priority mode PRIO (input priority)
Following a switchover of the preselected input, the automatic system switches back to this
priority input as soon as a signal reappears. Switchover is delayed for the set delay times.
If the signal fails at both the operating input and the standby input, the priority input remains
active.
Note
By setting the Automatic Ready After Change Over switch position to OFF you can pre-
vent an "automatic" return to the dominant input when the signal comes back. The switcho-
ver to the dominant input then only takes place when you press the 
Reset Fault
 key.
Priority mode EQUAL (equal input priority)
Following a switchover of the preselected input, the standby input with the same priority re-
mains active until the input signal fails on this input also. The automatic system switches
back to the preselected input, but only if a signal is present on it once again. Switchover is
delayed for the set delay times.
Note
Selecting this operating mode keeps to a minimum the number of switchover operations
and in certain cases the number of breaks in transmission (in the case of unsynchronized
input streams).