Chapter 5
Operating
2100.4400.32
- 5.84 -
E-2
9.2.3
TV Settings > ATV > Vision > Sync Pulse
9.2.4
TV Settings > ATV > Vision > Equalizer
Setting item
Explanation
Regeneration
Used to switch sync-pulse regeneration on or off
Sync Amplitude
Used to set the amplitude of the regenerated sync pulse (with regenera-
tion switched on)
Display
Explanation
Sync Monitoring
Indicates the status of sync-pulse monitoring of the input signal. The fol-
lowing may be displayed:
– OK: A standard input signal is being applied
– no V: No V-pulse frame detected
– no H+V: No V and H-pulse frame detected
– too low: Sync-pulse amplitude is less than 50% of the nominal sync-
pulse amplitude; the processed signal is, however, available at the 
encoder output
Sync Amplitude Input
Displays the measured input amplitude [mV] of the sync pulse. If the 
selected scanning line is not found in the input signal, the measurement 
value 0 mV is displayed.
Sync Amplitude 
Output
Displays the measured output amplitude in [mV] of the sync pulse
Setting item
Explanation
Diplexer