Справочник Пользователя для Rohde & Schwarz Inc SLV8000
Chapter 5
Operating
2100.4400.32
- 5.98 -
E-2
11.3
System Setup > SNMP Submenu
The operating software of the transmitter has an agent. This agent can communicate with
a remote management station that is used for monitoring and remote control via SNMP pro-
tocol. The agent is configured in the menu windows of the System Setup > SNMP menu.
a remote management station that is used for monitoring and remote control via SNMP pro-
tocol. The agent is configured in the menu windows of the System Setup > SNMP menu.
Menu windows
The SNMP menu branches to the following menu windows:
Setting item
Explanation
Protocol Type
Used to select the protocol type for external communication
– OFF: Communication is deactivated
– Bitbus: BitBus protocol is activated
– I20x: I20x protocol is activated (via serial interface only)
– Bitbus: BitBus protocol is activated
– I20x: I20x protocol is activated (via serial interface only)
Port Type
Used to select the port type
– TCP: Ethernet remote interface
– RS-232-C: D-Sub interface
– RS-485: D-Sub interface
– RS-232-C: D-Sub interface
– RS-485: D-Sub interface
Port
Used to select the logical port number for the BitBus communication via
Ethernet
Ethernet
Baudrate
Used to set the transmission rate for port type RS-232-C or RS-485
I20x Address
Used to configure the protocol address to Exciter A or Exciter B for port
type RS-232-C or RS-485
type RS-232-C or RS-485
Checksum
Used to switch CRC-secured transmission on/off
The same setting must be made for the recipient of the messages.
Display
Explanation
Connected
ON: Indicates that a connection to the called station exists
Context menu
Explanation
Reconnect
This function is used to set up the connection again after changes have
been made to the settings