Chapter 4
Commissioning
2100.4400.32
- 4.5 -
E-2
2.1.2
Configuring Remote Connection
If a remote Ethernet connection is to be used, you must configure the interface 
X31
 (
ETH-
ERNET REMOTE
) in such a way that it is in the subnet of your remote monitoring system.
1. Select System Setup > Ethernet.
The Ethernet window opens.
2. Under Rem.IP Address and Rem.Subnet mask, set the appropriate IP address and sub-
net mask.
3. If a gateway is used, configure its IP address too.
4. Perform a reboot of the instrument.
2.2
Making Specific Settings for a TV Standard
2.2.1
Selecting TV Standard: DVB, ATSC or Analog TV
1. Select System Setup > Tx Type > Transmitter.
The Transmitter window opens.
Local Time
For setting the local time
Local time means the time of day or zone time at the station concerned.
Compared to world time (UTC = universal time coordinated), each time 
zone has a positive offset (for zones east of Greenwich) or a negative 
offset (for zones west of Greenwich). This offset is predetermined by the 
time zone and is always a multiple of a full hour, or occasionally of half 
an hour.
In some countries clock time is advanced by one hour in summer. The 
time offset relative to UTC then changes accordingly.
UTC Time Offset
For entering the time offset between local time and UTC
Setting item
Description