Set Default Parameter 
 
The MS916 can be reset to two types of defaults: factory defaults or custom 
defaults. Scan the appropriate bar code below to reset the MS916 to its default 
settings and/or set the scan engine’s current settings as the custom default. 
• 
Restore Defaults - Scan this bar code to reset all default parameters 
as follows. 
• 
If custom defaults were set by scanning Write to Custom 
Defaults, scan Restore Defaults to retrieve and restore the 
scan engine’s custom default settings. 
• 
If no custom defaults were set, scan Restore Defaults to restore 
the factory default values listed in Table 3-1 on page 26. 
• 
Set Factory Defaults - Scan this bar code to restore the factory 
default values listed in Table 3-1 on page 26. If custom defaults were 
set, they are eliminated. 
• 
Write to Custom Defaults - Scan this bar code to store the current 
scan engine settings as custom defaults. Once custom default 
settings are stored, they can be recovered at any time by scanning 
Restore Defaults