Time-out Between Same Symbol 
 
Parameter # 0x89 
When in Continuous triggering mode, this parameter sets the minimum time 
that must elapse before the scan engine decodes a second bar code identical 
to one just decoded. This reduces the risk of accidently scanning the same 
symbol twice. It is programmable in 0.1 second increments from 0.0 to 9.9 
seconds. 
 
 
 
 
 
To set a time-out between same symbol, scan the bar code below. Next scan 
two numeric bar codes beginning on page 77 that correspond to the desired 
time-out. Single digit values must have a leading zero. For example, to set a 
time-out of 0.5 seconds, scan the bar code below, then scan the “0” and “5” bar 
codes. To change the selection or cancel an incorrect entry, scan Cancel on 
page 78
 
 
Beep After Good Decode 
 
Parameter # 0x38 
Scan this symbol to set the scan engine to beep after a good decode.