Справочник Пользователя для Unitech Electronics Co. Ltd. MS916BT
- 73 -
•
K = GS1-DataBar
•
L = Bookland EAN
•
M = Trioptic Code 39
•
N = Coupon Code
•
R = GS1 DataBar-14, GS1 DataBar Limited, GS1 DataBar Expanded.
Prefix/Suffix Values
Parameter # P = 0x69, S1 = 0x68, S2 = 0x6A
A prefix and/or one or two suffixes can be appended to scan data for use in
data editing. To set these values, scan a four-digit number (i.e. four bar codes)
that corresponds to ASCII values. See the Table B-5 on page B-7 and Numeric
Bar Codes on page 77. To change the selection or cancel an incorrect entry,
scan Cancel on page 78. To set the Prefix/Suffix values via serial commands,
see Setting Prefixes and Suffixes Via Serial Commands on page B-7.