118
2900H EN 20071108
Advanced operation (Key-operator mode)
D
RYSTAR
5500/5503 R
EFERENCE
MANUAL
Print head profile calibration
To start the manual print head profile calibration:
1
Perform step 1 to 2 of the
procedure on page
to select the ‘Calibration’ screen.
2
Press the Down key once to select ‘Printhead profile’, and press the Confirm key.
The ‘Select input tray’ screen appears:
3
Press the Up/Down arrow keys to select an input tray, followed by the Confirm
key (e.g. choose upper input tray).
key (e.g. choose upper input tray).
The system will start with Phase 1 of the calibration: Registration:
As a result, the ‘Registration’ print out appears.
Print head profile calibration must be done whenever the profile of the
print head needs to be improved (manual print head profile calibration).
For more information on maintaining image quality, refer to
print head needs to be improved (manual print head profile calibration).
For more information on maintaining image quality, refer to
on page
In the procedure, we will assume a print head profile calibration on the upper input
tray. The procedure for the lower input tray is identical.
tray. The procedure for the lower input tray is identical.