Справочник Пользователя для Honeywell International Inc. THX9421R02

Скачать
Страница из 132
 
39
 
69-2740EFS—01
 Troubleshooting
If you have difficulty with your thermostat, try these suggestions. Most problems can 
be corrected quickly and easily.
Screen is blank   Check circuit breaker and reset if necessary.
 Make sure power switch at heating and cooling system is on.
 Make sure furnace door is closed securely.
Screen is 
difficult to  
read
 Change screen brightness using Preferences menu (see page 27).
 At 2 am each day, Prestige thermostats change screen colors for an 
hour, to prevent burn-in. Touch the screen at any time to restore pre-set 
screen colors.
Heating or 
cooling system 
does not 
respond
 Touch 
SYSTEM
 to set system to Heat. Make sure the temperature is set 
higher than the Inside temperature.
 Touch 
SYSTEM
 to set system to Cool. Make sure the temperature is set 
lower than the Inside temperature.
 Check circuit breaker and reset if necessary.
 Make sure power switch at heating & cooling system is on.
 Make sure furnace door is closed securely.
 If “Waiting For Equipment” is displayed, the compressor protection timer 
is on. Wait 5 minutes for the system to restart safely, without damaging 
the compressor.