Справочник Пользователя для Integrated Microwave Technologies LLC. 25VST-AMP

Скачать
Страница из 34
25VST-AMP
 User Manual
 
 
 
Revision 1.0 
 
 24 
 
Figure 4-4:  Booster Amplifier Connectios 
 
4.6  Application Limitations 
4.6.1  Shielding Integrity 
When this device is integrated into a user configuration, care shall be taken to maintain Radio Frequency (RF) 
shielding integrity.  All RF paths shall employ coaxial cable and high-quality RF connectors.  Integration 
drawings and photographs shall be provided to IMT for review upon request.  IMT retains responsibility for the 
function of this device as designed and granted.  Device integrators assume responsibility for ensuring that the 
installed environment is equivalent to the reference design environment, and for maintaining RF performance 
integrity as related to integration and installation. 
 
The antenna for this device shall be installed with a separation of not less than 20cm from other antennas in 
the installed environment.  This recommendation is for system-to-system isolation.  More separation might be 
necessary, depending on the characteristics of other systems present. 
4.6.2  RF Power Measurement 
Upon completion of integration, and prior to commencing transmitter operation, an RF output power 
measurement shall be made to ensure that the output power does not exceed 5W. 
4.6.3  FCC RF Exposure Requirements 
This device is intended for application as a mobile radio transmitter, and it produces RF energy when 
transmitting.  The Federal Communications Commission (FCC) requires that RF Exposure to personnel be 
Power Input 
Audio Input 
Video Input 
RF Output