ChannelMaster Truck Package (PS18 & HPA/UHPA)
18
3.2.8
Diplexer Option Installation - Install Diplexer on RF output connector of ChannelMaster (N type
Connector). Attach RF cable from Nycoil to output of Diplexer (N type connector). (Refer to Figure
3-8). (The Diplexer is used to combine the +24 power and control signals onto the RF Coax Center
Conductor).
On later versions this step requires lifting up of the integrated fan housing, which may require the
drawer assembly to be pulled forward from the rack on the mounting rails.
Connector). Attach RF cable from Nycoil to output of Diplexer (N type connector). (Refer to Figure
3-8). (The Diplexer is used to combine the +24 power and control signals onto the RF Coax Center
Conductor).
On later versions this step requires lifting up of the integrated fan housing, which may require the
drawer assembly to be pulled forward from the rack on the mounting rails.
Figure 3-8: Connecting Cable to ChannelMaster RF Output
CAUTION!
DO NOT measure RF power with a Power Meter inserted in the RF + DC
path of the coxial cable UNLESS the power connector
(with purple and black wires) shown above has been disconnected.