Справочник Пользователя для Applied Concepts Inc ACMI007
Applied Concepts 011-0131-00 rev 2
Page 49
Configure Traffic 232 x.x.x.cfg is for a Traffic Speed Sensor version x.x.x.
Configure Stationary 232 x.x.x.cfg is for an RS-232 Stationary Speed Sensor.
Configure Stationary 485 x.x.x.cfg is for an RS-485 Stationary Speed Sensor.
Configure Speedometer 232 x.x.x.cfg is for an RS-232 Speedometer Speed Sensor.
Configure Speedometer 485 x.x.x.cfg is for an RS-485 Speedometer Speed Sensor.
These files are installed in the C:\Program Files\Stalker\Configuration Utilities folder.
Configure Stationary 232 x.x.x.cfg is for an RS-232 Stationary Speed Sensor.
Configure Stationary 485 x.x.x.cfg is for an RS-485 Stationary Speed Sensor.
Configure Speedometer 232 x.x.x.cfg is for an RS-232 Speedometer Speed Sensor.
Configure Speedometer 485 x.x.x.cfg is for an RS-485 Speedometer Speed Sensor.
These files are installed in the C:\Program Files\Stalker\Configuration Utilities folder.
Application Control File
The control file, Dashboard.ini, is an ASCII text file that may be edited with any text
editor such as WordPad or Notepad. It has several control parameters that can be
changed to affect the operation of the Speed Sensor application. See a copy of the file
below with explanations of the parameters following.
editor such as WordPad or Notepad. It has several control parameters that can be
changed to affect the operation of the Speed Sensor application. See a copy of the file
below with explanations of the parameters following.
[Stalker]
PORT=COM1
BAUD=9600
SOURCE_ID=1
DESTINATION_ID=2
CONFIG_FILE=C:\Program Files\Stalker\Configuration Utilities\Configure Stationary 232 2.0.0.cfg
CONFIG_FILE_LOCATION=C:\Program Files\Stalker\Configuration Utilities
GET_CFG_INTERVAL=5000
RESPONSE_TIMEOUT=500
RETRY=2
EE_FORMAT_INTERVAL=100
ENABLE_SPEED_LOGGING=1
LOG_ALL_SPEED_DATA=0
DATA_LOG_FILE=Speed Log.csv
PORT=COM1
BAUD=9600
SOURCE_ID=1
DESTINATION_ID=2
CONFIG_FILE=C:\Program Files\Stalker\Configuration Utilities\Configure Stationary 232 2.0.0.cfg
CONFIG_FILE_LOCATION=C:\Program Files\Stalker\Configuration Utilities
GET_CFG_INTERVAL=5000
RESPONSE_TIMEOUT=500
RETRY=2
EE_FORMAT_INTERVAL=100
ENABLE_SPEED_LOGGING=1
LOG_ALL_SPEED_DATA=0
DATA_LOG_FILE=Speed Log.csv
PORT defines the PC serial port used for communication with the Speed Sensor. When
the serial port is changed using the Options pull-down “Change Serial Port Settings”
function, this parameter in the Dashboard.ini file is automatically changed. It can also be
changed by editing the file. After the COM port is changed, the application needs to be
closed and re-opened for the newly selected port to be used.
BAUD defines the baud rate to be used for communication with the Speed Sensor. As
with PORT above, this parameter can also be changed via the Options pull-down
“Change Serial Port Settings” function or by editing the file. And after changing the baud
rate, the application needs to be closed and re-opened for the setting to take effect.
SOURCE_ID is always set to 1 and DESTINATION_ID is always set to 2. When
communicating with a Speed Sensor, the application is always the master of the link (ID
1) and the Speed Sensor is always the slave (ID 2). Do not change these values.
CONFIG_FILE defines the Speed Sensor configuration file used during a session, and
CONFIG_FILE_LOCATION defines the path to that file. These parameters are updated
by the application when “Select New Startup Config File” is selected from the Config
pull-down menu. The content of configuration files is discussed in detail in the next
section.