Справочник Пользователя для Panasonic Healthcare Co. Ltd. 9TB097DSS

Скачать
Страница из 40
28
     LKM-A111-BC / LKM-A111-BD / LKM-A121-BC / LKM-A121-BD
Drive Operation
Loading a Cartridge-tape
Insert a cartridge-tape into the cartridge-tape inserting door on the front panel with the
arrow on the cartridge-tape pointing towards the drive.  As the Cartridge-tape is inserted,
the drive takes it and automatically loads it into drive mechanism.
Unloading a Cartridge-tape
The cartridge-tape can be removed from the drive unit either in response to a SCSI Unload
Command, or by pressing the eject button.
By pressing Eject button, the drive ejects the cartridge-tape  from the cartridge-tape
inserting door.
Write-protecting a Cartridge-tape
Cartridge-tapes can be write-protected by sliding the tab on the back of the cartridge-tape.
In this state, data can be read from the tape but not written onto it.
Write-disable
Write-enable
Movable Element of
The Write-inhibit hole
Label area (depth : 0.5)
To avoid condensation onto the cartridge, the Library and cartridge must be kept away from
quick fluctuation (15 deg/ hr)  in temperature. If the ambient temperature changes suddenly,
leave around 12 hours in suitable environment before you use it again.
Life extension period of cartridge tape depends on environmental condition, usage and
cleaning cartridge tape. We recommend back up act less than 300 times and to exchange new
cartridge tape as soon as you are aware of failure.
Using a Cleaning Tape
In case of the drive unit, a cleaning function is built in the drive and hence, a periodic
cleaning using cleaning tape such as other format requires is not necessary.  However,
when the drive does not recover at the worst case, cleaning tape is recommended to use.
Note : For details of cleaning tape, refer to " System Requirements " in Page 20.
About the Cartridge Tapes