Chapter 5:
Defining Communications
RTMS Sx-300 User Guide
©2014 Image Sensing Systems Inc.
5-18
4. Once a connection is made, in the right pane you can:
Alter communication speed (baudrate). 
115200 bits per second (bps) is the factory default for serial units. 
Data rates below 9600 are useful where high quality transmission lines 
are not available. When using data rates below 9600 bps, the Autoscope 
RTMS Sx-300 data mode must be set to STAT to reduce the amount of 
data and prevent communication problems. See 
 for further details.
Change whether the connection is RS-232 or RS-485.
Activate RTS/CTS handshaking if the cable used for the connection is wired 
for it.
5. When finished, click Send.
NOTE:  Once you change the settings, you may lose the connection to the Autoscope 
RTMS Sx-300. If this happens, enter the connection parameters on the left 
side of the screen and click OK.