Installation Manual                                                                                                   Appendix B-3      
 
JP12 (Loiter Time Extend Disable) 
  Factory Default IN 
This jumper determines the timing range of 
the Loiter Timer potentiometer (R110) 
 
Table B.7 JP12 
Position   Time Range 
In 10-60 
seconds 
Out 65-110 
seconds 
 
JP13 (Piezo Enable) 
  Factory Default IN 
This jumper controls whether the piezo is 
enabled or disabled.  
 
Table B.8 JP13 
Position   Piezo is: 
In Enabled 
Out Disabled 
 
JP14 (Bar Display Enable) 
  Factory Default IN 
This jumper will enable the bar display  
LED 13 to function for installing or testing 
purposes.  
 
JP15 (TX Output LED Enable) 
  Factory Default IN 
This jumper will enable the Tx Output LEDs 
(LED1, LED2 and LED3) for installing or 
testing purposes. 
 
JP16 (Door Ajar Reset) 
  Factory Default IN 
This jumper will determine whether the 
Door Ajar alarm automatically resets. 
 
Table B.9 JP16 
Position  Door Ajar Automatically Resets? 
In Yes 
Out No