Справочник Пользователя для Selex Sistemi Integrati Inc. VOR2

Скачать
Страница из 254
Model 1150A DVOR 
 
Rev. -  November, 2008 
 
This document contains proprietary information and such information may not be disclosed 
to others for any purposes without written permission from SELEX Sistemi Integrati Inc. 
3-61
3.6.8.7.6
Change the Reference Depth of Modulation
To  affect  both  Transmitter  #1  and  Transmitter  #2,  select  Transmitters  >>  Configuration  >>  Nominal.    Adjust  the 
Reference depth of  modulation by selecting the  Reference  Modulation parameter  with the  mouse then either enter 
the value or use the spin controls. Press the Apply button (or the “F7” key) to apply the change.   
 
To affect only one transmitter, select Transmitters >> Configuration >> Offsets and Scale Factors screen Adjust the 
Transmitter 1 (or 2, as desired) Reference Modulation Scale Percent by selecting the parameter with the mouse, then 
either  enter  the  percentage  value  or  use  the  spin  controls.  Press  the  Apply  button  (or  the  “F7”  key)  to  apply  the 
change. 
 
3.6.8.7.7
Change the Sideband Power Level
To  affect  both  Transmitter  #1  and  Transmitter  #2,  select  Transmitters  >>  Configuration  >>  Nominal.    Adjust  the  
SBO power output level by selecting the SBO RF Level parameter with the mouse then either enter the value or use 
the spin controls. Press the Apply button (or the “F7” key) to apply the change. The value entered is a percentage of 
the  maximum  available  for  the  SBO  amplifier.  Note  that  the  power  change  of  the  Output  Power  level  in  the 
Transmitters >> Configuration >> Nominal Screen also affects the SBO RF Level.  
 
To affect only one transmitter, select Transmitters >> Configuration >> Offsets and Scale Factors screen. Adjust the 
Transmitter 1 or 2 (as required) Sideband 1 RF level by selecting the Sideband 1  RF Level Scale parameter with the 
mouse then either enter the percentage  value or use the spin controls. Press the  Apply button (or the  “F7” key) to 
apply the change. Note that a  value of 100% scales the Sideband 1 power output by 1.0, and a value of 70.7% scales 
the Sideband 1 power output by 0.5 (since this is a Voltage Scale Factor). Sidebands 2, 3, and 4 can also be adjusted 
individually in this screen.  
 
3.7 RMM
The RMM uses the same hardware and software as the PMDT but interconnects to the equipment via a modem and 
a telephone circuit.  The software screens and operator selection of this usage of the PMDT are described above in 
the PMDT paragraphs