Model 1150A DVOR 
 
2-38 
Rev. -  November, 2008 
 
This document contains proprietary information and such information may not be disclosed 
to others for any purposes without written permission from SELEX Sistemi Integrati Inc. 
The  U37  buffer  reads  TACAN  antenna  controller  signals  which  enter  through  connector  P1  and  are  converted  to 
TTL by U34. The U38 output latch directs activity of the TACAN antenna controller after the U38 latch signals are 
converted  to  RS422  by  U35  and  U36.  The  U38-19  loop-back  signal  may  be  used  for  fault-isolation  purposes  to 
buffer  U37-9.  Latch  U38-16  also  controls  ~TACAN_RESET  though  transistor  Q5  and  TVS  diode  CR42  before 
routing to P1-C8. 
 
2.3.2.11 Interface CCA Theory
The  Interface  CCA  provides  interface  connections  between  the  RMS/Facilities/Control  Backplane  CCAs  and  the 
outside world. Examples include spare analog and digital inputs, spare digital outputs, temperature sensors, smoke 
detector,  intrusion  sensor,  and  a  TACAN  antenna  controller.  RS232  communications  are  provided  to  RCSU  and 
PMDT terminals as well as an optional Ethernet module. All signals are protected by transient voltage suppression 
(TVS) devices on the Interface CCA before exiting. 
 
2.3.2.12 Interface CCA Block Diagram Theory
NOTE 
TACAN interfaces are described but not used in the VOR system. The Interface CCA is also 
used in DME/TACAN systems. 
 
Refer to 
All connections between the Interface CCA and the RMS/Facilities/Control Backplane CCAs 
are accomplished via  headers J1 and J2. The J2 and J3 connections  will not be used in  a VOR system since there 
will not be a TACAN antenna system controller. 
 
Connectors  J5  and  J6  are  DB9-types  which  provide  interface  to  the  RCSU  and  PMDT  terminals  mentioned 
previously. 
 
Connector J7 is an RJ11 phone jack provided for exterior temperature sensing. 
 
Connector J8 is a header provided for in-factory test purposes. 
 
Connector  J9  is  an  RJ45 jack  intended  for  use  as  an  Ethernet  port. The  port  will  be  powered  by  a  +3.3V  DC-DC 
converter (PS1). 
 
Terminal  block  TB1  facilitates  connection  of  up  to  ten  spare  analog  inputs,  four  digital  inputs,  and  four  digital 
outputs.  
 
Terminal  block  TB2  allows  connection  of  the  RCSU  and  Dial-Up  modem  tip  and  ring  signals.  These  signals  are 
transient  protected  by  common-mode  chokes  as  well  as  spark-gaps,  sidactors,  and  power  resistors.  INTERLOCK 
and EXT_KEY_IN signals are TVS-protected and optically isolated. True isolation for these signals may be enabled 
or  disabled  depending  on  the  strapping  of  JP1  and  JP2.  EXT_KEY_OUT  signals  are  optically  isolated  and  TVS-
protected before exiting via TB2. 
 
SMOKE_DETECTOR,  INTRUSION_SENSOR,  ILS-VOR_RX_232,  and  ILS-VOR_TX_232  signals  are  TVS-
protected  before  further  routing.  DET_IDENT1  and  DET_IDENT2  signals  are  scaled  as  well  as  TVS-protected 
before exiting via TB2.  
 
Earth ground lug E1 provides a return path for all transient voltage protection devices on the Interface CCA.