EdgeReader and EdgePlus 
EH400, EHR40, EHRP40, EH400-K
82000-920 A.1
 INSTALLATION GUIDE
4
©2009 HID Global Corporation. All rights reserved.
Contact
Contact Edge through one of the following methods:
Direct Connect
If Edge will be connected to a network using static IP addressing or if the Discovery GUI is not installed on the PC, use this method.
Note: The computer must be running Windows 2000 or XP and be configured for DHCP.
1.  Disconnect the computer from the network and directly connect Edge to the computer with an Ethernet cable.
2.  Click 
Start > Run. Enter ipconfig /renew 
3.  Access a web browser and enter 
169.254.242.121 into the Address field 
OPIN Discovery/Update Application
Use the 
OPIN Discovery / Update Application on a computer to locate, connect and update Edge.  
System Requirements:  Java 6.0 or later. Go to 
 to download.
Operating Systems: 
Windows XP and Fedora 8.
Find the OPIN Discovery / Update Application at 
www.ShareMethods.com
 > 
OPIN > Firmware > 2.3.x. Save the files to your local 
harddrive.
The Edge must be connected to the network, and power applied, before the device is discovered.
1.  With a computer connected to the same network as Edge, double-click 
opin-update.jar
The OPIN Discovery / Update Application 
opens and the 
Controller Table populates.
Note: If the Controller Table does not populate, go to Edit > Broadcast Address. The default broadcast address is 
255.255.255.255. Some network switches may block this transmission. If this is the case, change the subnet to match the 
network, for example 10.7.255.255. Click 
Save.
2.  Select the desired device from the list.
3.  From 
Path to Update Package frame, browse to the firmware location on the computer.
4.  Click 
Install. Firmware is installed.
EH400 - Provides additional functionality to not only Install firmware, but to Changeover, and Rollback firmware updates. Once 
firmware is installed, click 
Changeover to switch to the updated firmware. Click Rollback to switch back to the previoius firmware 
version.
5.  View the 
Status Log for each status while performing Discovery and Update functions.
Configure
The web browser will prompt for login information.  From the 
Login screen enter admin, leaving the Password field empty.  
Follow the instructions on the web browser screen to configure Edge.
Hi-O Interface Modules
Hi-O interface modules are used to interface the Edge device (EdgeReader or EdgePlus) with door electronic components. Components 
include access control readers, strike, magnetic lock, request to exit, door position switch, and auxillary devices.
For Hi-O interface module wiring, see their prospective Installation Guides.
Go to 
www.hidglobal.com
 > 
Knowledge Center
 > 
Resources
 > 
Document Library
. Search the document type as a 
Installation Guide.
Model
Description
Part Number
EDM-M
EdgeModule Door
82342
EIM-M
EdgeModule Input
82340
EWM-M
EdgeModule Wiegand
82360
EDWM-M
EdgeModule Door & Wiegand
82363AM
ELM
EdgeModule Lock
82301
EVM
EdgeModule Voltage
82365