Overview
This document describes how to install and operate the HID ProxTrak
 (Also known as 4043A
AMH100 HandHeld Reader) HandHeld Reader. The HID HandHeld Reader is a unit designed to
work in conjunction with the Symbol PDT 6100 HandHeld Computer.  Together, the system is
capable of reading from and writing to an IBM PC with the AssetID™ Radio Frequency (RF)
interface.  The HandHeld Reader unit is connected to the Symbol 6100 unit via a coiled cable
with an RJ-45 style connector.  When connected, the HID HandHeld Reader and HandHeld
Computer (PDT 6100) communicate through an RS-232 protocol.  The HID HandHeld Reader
receives power as well as commands from the HandHeld Computer.  When the HandHeld
Reader receives a command from the HandHeld Computer, it executes the command and sends
back the appropriate response to the HandHeld Computer.
Hardware Setup
1.  Connect the RJ45 connector at the end of the HandHeld Reader into the Symbol PDT6100
HandHeld computer.
2.  Turn on the HandHeld Computer by pressing the round button near the lower right hand
corner of the display.
Operating the HandHeld Reader
1.  Select the desired command/process from the menu of the Symbol HandHeld Computer.
2.  When a command is entered, the LED on the HandHeld Reader flashes red and continues to
flash red approximately every 3 seconds while no tag is in the field.
3.  When the HandHeld Reader is placed within range of a tag, the HandHeld Reader LED
continues flashing red at an increased rate indicating that the HandHeld Reader unit is
working.
4.  The HandHeld Reader flashes green for approximately 250ms after a successful execution of
a command or until a subsequent command is received.
5.  If there is no tag detected, the HandHeld Reader sends back a “no tag” message to the
HandHeld Computer.
6.  If the command sent to the tag fails, a failure message will be sent to the HandHeld
Computer.
Tag Orientation
It is important to orient the HandHeld Reader correctly for a successful read/write of the tag.
HandHeld Reader Orientation – PC in a box
1.  Locate the target symbol on the outside of each box. See figure 1.
2.  Hold the HandHeld Reader parallel to the tag located behind the Asset ID
 target symbol on
the box. Refer to the orientation diagram seen in figure 2 for correct positioning.
3.  The HandHeld Reader should be held vertically for a desktop computer box and horizontally
for a tower computer box. Note that for the desktop, the HandHeld Reader is actually
oriented 90
°°°°
 from the words Asset ID™ on the target label.