Справочник Пользователя для HID Global Corporation 4045

Скачать
Страница из 60
 
ENTRYPROX – 4045-907  REV A 
34 
CHANGING OPERATING PARAMETERS 
Many users will use the EntryProx with the factory default 
operating parameters.  The following commands include 
some of the most commonly customized parameters.  For 
further refinements on EntryProx operation, review the 
options shown in Table 2. 
 
CHANGING THE MAIN RELAY TIME 
The main relay time applies to all users 1-2000. The factory 
default main relay time is five (5) seconds. Main relay time 
can be set from one to ninety-nine seconds in one-second 
increments using Command 11. 
1. Place the EntryProx unit in program mode. Press: 
99 # Master Code * (default is 1234) 
2. Enter the new main relay time, in seconds (from 1 
to 99). For example, to enter 10 seconds, press: 
11 # 10 # 0 # ** 
3. Press *  to exit program mode. 
 
INVALID PIN LOCKOUT 
Command 30, Option 18 allows you to enable or disable the 
Invalid PIN Lockout (IPL) feature.  This feature prevents 
unauthorized persons from gaining entry by guessing PIN 
codes or Master Codes.  When a preset number of invalid 
entries is exceeded (set by using Command 32 – option 4, 
default is 5) the EntryProx will either trigger the Forced Door 
output, or the keypad will be disabled for a user-configurable 
time period (select the action, using Command 30, option 19, 
and then set lockout time by using Command 32 – 5).    
 
The invalid PIN code count is reset to zero by any of the 
following: 
entering a valid keypad PIN 
presenting a programmed Prox card 
entering a valid [ 99 # Master code* ] sequence  
the expiration of the keypad timer