Справочник Пользователя для HID Global Corporation 6055BA

Скачать
Страница из 3
_____________________________________________________________________________________________________
HID Corporation  9292 Jeronimo Road   Irvine, CA 92618-1905 USA TEL (949) 598-1600  (800) 237-7769  FAX (949) 598-1690
Web page, E-mail - www.hidcorp.com - IQ Card Reader Installation Manual Addendum 6055-911 Rev A
Page 3 of 3
Install tape to secure coil and lead wires. The toroid above needs to be installed between the Power Supply
and the Reader in order to maintain CE compliance.
The Red Lead is connected to the + side of the Power Supply output.  The Black Lead is connected to the –
side of the Power Supply output.
The White Lead with a Red stripe is connected to the Red Lead of the Reader.  The White Lead with a Black
stripe is connected to the Black Lead of the Reader.
Install clamp-on ferrite part. Fairrite #0443164151 and torroid as shown in the schematic below.