1 Parts 
List 
 
PARTS LIST (Included) 
Quantity
- HID MIFARE Reader with snap-on 
cover and 18in.  
- #6-32 x 1” self-tapping panhead 
screw 
- Installation manual 
 
PARTS LIST (Not-Included) 
Quantity
- Wire splice 
- DC Power supply 12 VDC 
 
2 Mounting 
Instructions 
•  Determine an appropriate mounting location. The 
reader may be mounted to any surface, including 
metal. 
• 
Drill two (2) 3/32-inch (2.5mm) holes 
approximately 1 inch deep for mounting the 
reader. 
•  Drill a 5/8-inch (16mm) hole for the cable. 
•  A single-gang (2S) electrical junction box may 
also be used; reader fits US hole pattern, and the 
6-32 screws work with the J-box. 
•  Remove the snap-on cover from the reader and 
secure the reader to the mounting surface. 
•  Route the cable from the reader and/or power 
supply to the host. A linear type power supply is 
recommended. Check all electrical codes for 
proper cable installation. 
•  For the cable connection to the panel - use Alpha 
#1299C or equivalent.  
•  Test the operation of the reader (Section 4). After 
completion of the test, replace the snap-on cover. 
• See Figure 1 for product and mounting 
dimensions. 
•  For proper regulatory compliance, the drain wire 
should be disconnected at the power supply end 
of the cable. 
•  Changes or modifications not expressly approved 
by the party responsible for compliance could 
void the user’s authority to operate the 
equipment. 
•  The Reader is intended to be powered from a 
limited power source output of a previously 
certified power supply. 
3  Connecting the Reader 
•  Connect the reader to the host according to the 
wiring table below and the host installation guide. 
Signal 
Color 
DB9F 
DB25F  
9-14 VDC 
Red 
   - 
   - 
GND 
Black 
Pin 5 
Pin 7 
D0 
Green 
   - 
   - 
D1 
White 
   - 
   - 
GRN LED 
Orange 
   - 
   - 
RED LED 
Brown 
   - 
   - 
Beeper 
HOLD 
DSR 
RX 
DTR 
TX 
SHLD GND 
Yellow 
Blue 
Violet 
Pink 
Gray 
Tan 
Drain 
   - 
Pin 1 

Pin 2 
Pin 4 
Pin 3 
   - 
   - 
Pin 8 

Pin 3 
Pin 20 
Pin 2 
   - 
 
 
4  Testing and Operation 
•  When power is applied to the reader the beeper 
will beep and flash the LED green three times.  
•  Present an ID card to the reader. The LED will 
momentarily turn green while the beeper beeps 
once, indicating that the card was read 
successfully. 
•  Please note that typical read range for MIFARE® 
cards is .75 to 1.5” (20 – 37 mm). 
 
 
 
Important Product Specifications 
Power supply  
Absolute Maximum Voltage  
Maximum Current at 12V             
Operating Voltage Range             
Linear type 
16 VDC 
94mA 
9.0 – 14.0 VDC 
Maximum cable distance             
To host                                          
50 ft RS-232 
500 ft Wiegand 
Operating temperature range       
-30 to 65
°C           
 
FCC Compliance Statement: This device complies 
with part 15 of the FCC rules. Operation is subject to 
the following two conditions: (1) this device may not 
cause harmful interference, and (2) this device must 
accept any interference received, including 
interference that may cause undesired operation.