Product Specifications 
Read Distance 
¾
 
Overall Operating Limits (10VDC - minimum) 
1.0-1.5 inches (2.5-3.8 cm) 
¾
 
Non-Metallic Mounting (12VDC - typical) 
1.0-1.5 inches (2.5-3.8 cm) 
¾
 
Mounted on Metal (12VDC - typical) 
1.0-2.5 inches (2.5-3.8 cm) 
 
Environmental Characteristics 
¾
 
Operating Temperature Range 
-30
o
C to 65
o
C (-22
o
F to 150
o
F) 
¾
 
Storage Temperature Range 
-40
o
C to 85
o
C (-40
o
F to 185
o
F) 
¾
 
Operating Humidity Range 
5% to 95% non-condensing 
¾
 
Operating Vibration Limit 
.04 g
2
/Hz 20-2000Hz 
¾
 
Operating Shock Limit 
30g, 11mS, Half Sine 
¾
 
Potting Material 
UL Recognized Filled Polyurethane 
¾
 
Enclosure Material 
UL Recognized Lexan Polycarbonate 
¾
 
Potted Weight  
8.2oz (228grms) 
 
Power Requirements 
¾
 
Power supply 
Linear type recommended 
¾
 
Operating Voltage Range (+DC) 
10.0VDC -14.0VDC 
¾
 
Absolute Maximum (+DC non-operating) 
14.0VDC 
¾
 
Maximum Average Current at 12V 
60mA 
¾
 
Transient Protection (all terminals) 
8,000 volts 
¾
 
Reverse Voltage Protection 
-15V on all I/O and -35 for power lines 
¾
 
Input Voltage (maximum data-0/1 lines) 
15.0VDC 
¾
 
Input Voltage (maximum interface lines) 
15.0VDC 
 
Operating Parameters 
¾
 
Excitation Frequency 
13.56MHz 
¾
 
Read and Report Speed (26 bit Wiegand Card) 
200mS (1K card) + output data 
¾
 
Maximum Cable Distance to Host 
500 feet (152 meters) 
¾
 
LED Type                                                                      Bi-colored Red/Green 
¾
 
LED Operation (host control of red/green) 
<
.5V on LED control line 
¾
 
Beeper Operation (host control) 
<
.5V on beeper line 
¾
 
Beeper Control (default) 
Beeper enabled 
 
 
FCC Compliance Statement:  
This device complies with part 15 of the FCC rules. Operation is subject to the following two 
conditions: (1) this device may not cause harmful interference, and (2) this device must accept 
any interference received, including interference that may cause undesired operation. 
 
NOTE: THE ABOVE ARE RECOMMENDED INSTALLATION PROCEDURES.  ALL LOCAL, STATE 
AND NATIONAL ELECTRICAL CODES TAKE PRECEDENCE.