Справочник Пользователя для Microtek Electronics Inc WES
T
ROUBLE
S
HOOTING
PROBLEM SUGGESTION
No Link Activity
1. NO POWER – make certain the both
WEMs have power and the red Power LED
is on.
is on.
2. Check the configuration of both WEMs.
Each pair must be set to the same address.
If you have changed any of the advanced
settings, make sure the configuration of
both WEMs is the same.
If you have changed any of the advanced
settings, make sure the configuration of
both WEMs is the same.
3. Make sure the cable run between the WEM
and Ethernet device is no longer than 328
feet.
feet.
4. Make sure the cables being used are
straight through and all cable connectors
are attached properly.
are attached properly.
5. If using an Ethernet hub or fast switch, try
a crossover cable between the hub and the
Power Injector Module.
Power Injector Module.
No Signal Level LED
or Flashing Signal
Level LED
or Flashing Signal
Level LED
1. Check line-of-sight of the WEMs. Verify
the WEMs are aimed properly. You
should have clear, wide-open line of sight
between the WEM modules.
should have clear, wide-open line of sight
between the WEM modules.
2. Change channels; cycle power.
All three solid LEDs
but no picture
but no picture
1. Check video at the camera
2. Check wiring into encoders or decoders
3. Try changing channels; cycle power
4. Hook up one radio directly into a PC or
2. Check wiring into encoders or decoders
3. Try changing channels; cycle power
4. Hook up one radio directly into a PC or
laptop and verify that the IP address is
accessible. Check the other radio the same
way, then verify that each IP address is
accessible over the wireless link into a
PC/laptop.
accessible. Check the other radio the same
way, then verify that each IP address is
accessible over the wireless link into a
PC/laptop.
No Green Signal Level
LED (When Using the
MLWES-30 with two
18” Parabolic Dishes)
LED (When Using the
MLWES-30 with two
18” Parabolic Dishes)
1. Verify wide-open line-of-sight
2. Re-angle your dish antenna in a downward
angle until both LEDs are solid green.
3. Mount the dishes higher above ground
level and/or above any obstruction.
If you have tried the trouble shooting steps above and the system is still not working correctly,
please contact MicroTek at 888-366-4276, Monday through Friday, between the hours of
8:00AM and 5:00PM Pacific Time. One of our technicians will work with you to rectify the
problem over the phone.
Thank you,
MicroTek Electronics, Inc.
please contact MicroTek at 888-366-4276, Monday through Friday, between the hours of
8:00AM and 5:00PM Pacific Time. One of our technicians will work with you to rectify the
problem over the phone.
Thank you,
MicroTek Electronics, Inc.
- 14 -