SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL
eNfusion™ HSD-128 High-speed Data Terminal
C. HSD Maintenance Utility Program
This section describes the HSD maintenance port utility program and provides the
connection and cabling details required to access and use the program.
connection and cabling details required to access and use the program.
(1) General Overview
A maintenance utility program, built into the HSD and HSD-X transceiver’s operational
software, provides a system interface for fault isolation and diagnostic procedures.
Connection to this program is made through the RS-232 maintenance port interface.
software, provides a system interface for fault isolation and diagnostic procedures.
Connection to this program is made through the RS-232 maintenance port interface.
To use the HSD Maintenance Utility Program, an RS-232, VT-100 terminal (PC or
Laptop operating a terminal emulation program) must be connected to the HSD or
HSD-X transceiver.
Laptop operating a terminal emulation program) must be connected to the HSD or
HSD-X transceiver.
The maintenance port on the front panel of HSD transceivers provides a direct
connection to the HSD maintenance utility program using a DB25S connector.
Optionally, remote cabin access is possible using a DB9S connector via the ARINC
600 connector.
connection to the HSD maintenance utility program using a DB25S connector.
Optionally, remote cabin access is possible using a DB9S connector via the ARINC
600 connector.
Direct connection to the HSD-X’s front panel, maintenance port requires an HSD-X
maintenance port cable. The front connector, maintenance port supports trace and
data load functions and is a female, micro-D-type, M83513/04-B11N, or equivalent.
As well, a permanent connector wired to the rear, middle-plug, maintenance port
connector can be installed for remote access. A description of the HSD-X
maintenance port pins is provided in 305.
maintenance port cable. The front connector, maintenance port supports trace and
data load functions and is a female, micro-D-type, M83513/04-B11N, or equivalent.
As well, a permanent connector wired to the rear, middle-plug, maintenance port
connector can be installed for remote access. A description of the HSD-X
maintenance port pins is provided in 305.
For testing and monitoring of all components of a Multi-Channel HSD configuration,
access to all units in the system is achieved by using a single terminal (PC or Laptop)
connected to the Maintenance Port of the HSD-128 Transceiver. Communication with
any installed HSD-Xs installed in the system is possible by passing through the HSD’s
Maintenance Facility when operating in “console-mode.” Figure 4–1 illustrates the
Maintenance Port Facility in a Multi-Channel configuration.
access to all units in the system is achieved by using a single terminal (PC or Laptop)
connected to the Maintenance Port of the HSD-128 Transceiver. Communication with
any installed HSD-Xs installed in the system is possible by passing through the HSD’s
Maintenance Facility when operating in “console-mode.” Figure 4–1 illustrates the
Maintenance Port Facility in a Multi-Channel configuration.
Although system monitoring is possible using the “console-mode” feature, software
updates, if required, must be loaded directly to the HSD-128 and each HSD-X via
their respective maintenance port.
updates, if required, must be loaded directly to the HSD-128 and each HSD-X via
their respective maintenance port.
Table 4–2. List of Optional Test Equipment
Item
Equipment
Specification
Quantity
Service Provider
Information Package
Information Package
Special
Inmarsat service provider
1
Internet access
Standard
Inmarsat Swift64
high-speed-data
high-speed-data
1
High speed data terminal
Setup Guide
Setup Guide
Special
MN-1110-10048
1
Time Domain
Refectometer
Refectometer
Standard
–
1