Page 4–55
18 September 2007
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL
eNfusion™ HSD-128 High-speed Data Terminal
Figure 4–31. HSD ORT Sample Display (software version 5.7 or later)
(6) System Power-up Checks
Note:
Before proceeding, ensure that all pre power-up, mechanical, and electrical 
verifications have been successfully performed and documented using the 
Installation Checklist provided in "Installation Checklist" on page D-1.
(a) Preparation
The following tests serve primarily to confirm proper system power-up; therefore, 
they can be performed while the aircraft is still in the hanger. Ensure that a 
computer, configured as instructed on page 7, is available for testing.
(b) Initial Visual LED Verification
The system's Power ON and Fault LEDs provide a visual status indication on the 
HSD and HSD-X front panel and on the optional remote panel. 
 1.
Verify that the LEDs (at both locations) repeatedly cycle ON/OFF when 
power is applied.
 2.
Once the cycle has completed (~5 seconds), verify that the power LED 
remains illuminated.
(c) Initial Computer Power up Display
With the computer connected and configured to accept Maintenance Port data, 
power-up the HSD, and verify the initial power-up screen displays as shown in 
the example, Figure 4–32. The example provides a display using a Stand-Alone 
Mode installation.
ORT TOOL NAME:
ORT TOOL PART NUMBER:
ORT TOOL OEM VERSION:
ORT PART NUMBER:
CHECKSUM (stored at offset 464) 12133  OK
longest write cycle took 0 MSEC