SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL
eNfusion™ HSD-128 High-speed Data Terminal
F. Operational Mode and Configuration System Checks
This section describes system checks designed for specific HSD modes of operation.
(1) Verifying Cooperative Mode System Operation
This section provides system operational verification procedures that are specific to
Cooperative Mode installations.
Cooperative Mode installations.
The following system verification procedures use the HSD Maintenance Port Utility
Program to access system information.
Program to access system information.
Note:
Record all test results in "Installation Checklist" on page D-1.
Note:
Depending on the version of software and the system configuration installed,
the actual menus and screen displays appearing in “live” systems may differ
slightly from the illustrations provided in this document. The illustrations also
use “x.x” as a substitute for the actual firmware version.
the actual menus and screen displays appearing in “live” systems may differ
slightly from the illustrations provided in this document. The illustrations also
use “x.x” as a substitute for the actual firmware version.
(2) Verifying Honeywell Combined Mode System Operation
This section provides system operational verification procedures that are specific to
Honeywell Combined Mode installations.
Honeywell Combined Mode installations.
The following system verification procedures use the HSD Maintenance Port Utility
Program to access system information.
Program to access system information.
Note:
Record all test results in "Installation Checklist" on page D-1.
(a) Checking HPA Status
To check the HPA Status:
1.
With the Maintenance Port Utility program activated (MAINT password
access), press the equals sign (=) to activate the “Reports”.
access), press the equals sign (=) to activate the “Reports”.
2.
Press Ctrl+N to scroll to report 25.
3.
To toggle on the HPA ARINC I/O report, type 25.
Report 25 toggles ON.
4.
Press Esc.
The “Reports” for HPA Status appears on screen. The screen refreshes every
few seconds.
5.
Confirm that the report shows SSM as “normal operation” and that SDI
appears configured as HGA HPA. (See example provided above.)
appears configured as HGA HPA. (See example provided above.)
6.
Toggle OFF report 25. (Press = , then type 25. Report 25 appears as “OFF”).
HPA maintenance word 600002: SSM: NORMAL OPERATION SDI: HGA HPA
HPA status word 64137a: SSM: NORMAL OPERATION SDI: HGA HPA
OUTPUT POWER: 28.0 dB LESS THAN 40W
MAX. AVAILABLE RMS POWER: 2.0 dB GREATER THAN 40W
HELD POWER LINEAR CARRIER OFF BACKOFF RANGE= 31 dB
HPA status word 64137a: SSM: NORMAL OPERATION SDI: HGA HPA
OUTPUT POWER: 28.0 dB LESS THAN 40W
MAX. AVAILABLE RMS POWER: 2.0 dB GREATER THAN 40W
HELD POWER LINEAR CARRIER OFF BACKOFF RANGE= 31 dB