Справочник Пользователя для EMS Technologies Canada Ltd. HSD-X

Скачать
Страница из 366
Page 4–62
18 September 2007
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL
eNfusion™ HSD-128 High-speed Data Terminal
F. Operational Mode and Configuration System Checks
This section describes system checks designed for specific HSD modes of operation. 
(1) Verifying Cooperative Mode System Operation
This section provides system operational verification procedures that are specific to 
Cooperative Mode installations. 
The following system verification procedures use the HSD Maintenance Port Utility 
Program to access system information. 
Note:
Note:
Depending on the version of software and the system configuration installed, 
the actual menus and screen displays appearing in “live” systems may differ 
slightly from the illustrations provided in this document. The illustrations also 
use “x.x” as a substitute for the actual firmware version.
(2) Verifying Honeywell Combined Mode System Operation
This section provides system operational verification procedures that are specific to 
Honeywell Combined Mode installations. 
The following system verification procedures use the HSD Maintenance Port Utility 
Program to access system information. 
Note:
(a) Checking HPA Status 
To check the HPA Status:
 1.
With the Maintenance Port Utility program activated (MAINT password 
access), press the equals sign (=) to activate the “Reports”. 
 2.
Press Ctrl+N to scroll to report 25. 
 3.
To toggle on the HPA ARINC I/O report, type 25
Report 25 toggles ON.
 4.
Press Esc
The “Reports” for HPA Status appears on screen. The screen refreshes every 
 
few seconds.
 5.
Confirm that the report shows SSM as “normal operation” and that SDI 
appears configured as HGA HPA. (See example provided above.)
 6.
Toggle OFF report 25. (Press = , then  type 25. Report 25 appears as “OFF”).
HPA maintenance word 600002: SSM: NORMAL OPERATION  SDI: HGA HPA
HPA status word 64137a: SSM: NORMAL OPERATION  SDI: HGA HPA
OUTPUT POWER: 28.0 dB LESS THAN 40W
MAX. AVAILABLE RMS POWER: 2.0 dB GREATER THAN 40W
HELD POWER    LINEAR    CARRIER OFF    BACKOFF RANGE= 31 dB