Справочник Пользователя для EMS Technologies Canada Ltd. HSD-X

Скачать
Страница из 366
Page 4–73
18 September 2007
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL
eNfusion™ HSD-128 High-speed Data Terminal
This completes the first load of the Channel Card software selected in step 10.
 14.
For HSD transceivers with two channel cards, repeat all required software loads 
to both channel cards. 
 15.
Repeat steps 7 through 13 for all other required software loads of Channel Card 
Software files as specified in the applicable software service bulletin.
 16.
When all Channel Card Software is loaded, reset or cycle the power on the HSD 
transceiver. 
 17.
If no other software loads are required, proceed to "Verifying Software Loads" on 
page 4-78.
 18.
In the event that the load fails, restart the load from the beginning of the Loading 
Channel Card Software procedure. If after two attempts the load still does not 
complete successfully, assume that the software disks or files may have been 
corrupted or the software is incompatible with the hardware configuration. Contact 
EMS SATCOM product support for assistance. 
(2) Loading Control Processor Software 
CAUTION:  
When loading software to the units in installation environments that 
include an SDU, disable the SDU (Power off or remove the sdu from the 
arinc tray) before beginning the software load procedure.
HSD/HST LOADER   Vx.x -- Mon Mar 24 12:12:17 2003
which target ?
   0 = control processor
   1 = channel card #1
   2 = channel card #2
   3 = HPA application
   4 = data i/o card
   5 = HPA application with manual setup
   6 = HPA application plus boot with manual setup
   7 = HPA application plus boot
   8 = channel card #1 boot code
   9 = channel card #2 boot code
   11 = channel card #1 pic code
   12 = channel card #2 pic code
   13 = HCM application
   14 = HST ORT
   15 = HSD ORT
   16 = HSD-X ORT
?1 
File name, which contains the firmware image? applxx.hex
This download will require one of the PC's COM ports. (1, 2, etc) [1] ?
1
Connect COM1 of this PC to the maintenance port of the data terminal.
Hit <ESC> to abort, or <Enter> to proceed
Establishing communication to the data terminal -- DO NOT CYCLE THE POWER !!
Hit ESC to abort.
DATA TERMINAL APPARENTLY READY TO ACCEPT PROGRAM
switching to 57.6 kbaud
loading applxx.hex
1% 5% 10%