Справочник Пользователя для EMS Technologies Canada Ltd. HSD-X

Скачать
Страница из 366
Page 2–23
18 September 2007
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL
eNfusion™ HSD-128 High-speed Data Terminal
(5) Configuring System Parameters for Multi-Channel Configurations
This section describes how to use the HSD Maintenance Port Utility to configure the 
HSD system parameters for operation in Multi-Channel Configurations.
Refer to "Test and Fault Isolation" on page 4-1 for detailed instructions on how to 
connect to and use the HSD Maintenance Port Utility Program. 
When all the required system parameters have been configured, “reset” or cycle the 
power on the HSD to activate the new configuration.
To configure the required system parameters first establish a connection to the HSD 
Maintenance Port Utility program:
Connect a computer to the maintenance port of the HSD transceiver as described 
in "Test and Fault Isolation" on page 4-1, and then power up the system.
Using a terminal emulation program, open the HSD maintenance utility program.
Type the password MAINT. (The password does not appear on the screen.)
The HSD Maintenance Port Utility Program Menu 1 appears. You are now ready to 
begin configuring the system parameters for Multi-Channel operation as described in 
the following sections.
(a) Configuring the Terminal Category for Multi-Channel 
If the HSD transceiver does not have the recommended hardware strapping for 
system configuration installed, the terminal category must be configured using 
the HSD Maintenance Port EEPROM parameters.
To configure the Terminal Category:
 1.
In Menu 3, to select misc. EEPROM parameters press M.
The Miscellaneous Parameters list appears. The available parameters may 
differ depending on the version of control processor software installed.
 2.
To select the Terminal Category, type 16 and then press Enter.
The Terminal Category Menu appears.
MENU 3                            FIRMWARE Vx.x
L     list EEPROM                       S     list event log
M     misc.  EEPROM parameter           F     list call log 
O     list ORT                          P     ocean region parameter
I     set all LES id’s
<CTRL> N  next menu      <CTRL> O  previous menu      =  select reports
MISCELLANEOUS PARAMETERS
 1  HPA-TO-ANTENNA TOTAL LOSS        11  FRONT PANEL LEDS ENABLED
 2  FORWARD ID                       14  MAINTENANCE PORT INVERSE VIDEO
 3  GPS PROTECTION ALGORITHMS        15  MAINTENANCE PORT DEGREES SYMBOL
 4  REGISTRATION REQ'D BEFORE CALLS  16  TERMINAL CATEGORY
10  NUMBER OF CHANNEL CARDS          17  VIPER ANTENNA GAIN
WHICH PARAMETER #  <CTRL> N for next page  ? 16