       Paragon4 – UHF, 700  & 800MHz User Manual 
 
 
 
 
61 
Item 
Description 
Analog alarms trap conditions 
Analog Monitoring Rate 
Frequency at which internal values are updated and checked against the alarm 
boundary conditions. Ranges from 100milliseconds to infinity. Default = 500ms 
Analog alarms settings 
For each diagnostic value displayed, the user can control alarms trap conditions 
in the following ways: 
 
Set acceptable range of values by entering the low and high thre-
sholds 
 
Choose to be notified when the value goes out of acceptable range by 
selecting the “goes out of range” check box 
 
Choose to be notified when the value returns into acceptable range by 
selecting the “returns into range” check box 
All monitoring combinations are possible  
Digital  Alarms trap conditions 
Digital Alarms settings 
For all digital alarms, the traps can be sent when: 
 
“Asserted:-The digital signal changes from low to high 
 
“Unasserted”-The digital signal changes from high to low 
All monitoring combinations are possible 
Hardware fault trap conditions  
Receiver Comparison 
To diagnose a  possible receiver malfunction  
 
Choose to be notified when a Receiver Comparison fault occurs by se-
lecting the "Fault" check box.  
 
Choose to be notified when a Receiver Comparison fault has been cor-
rected by selecting the "Fault cleared" check box.  
Calibration Files 
Calibration Files 
All Paragon4 unit firmware comes bundled with two interpolation files used for 
forward and reverse power calibration. These files are required to be used with 
the optional external power sensor assembly (p/n 030 03547-xxx). 
Caution: Forward & reverse power readings will not be accurate without the 
optional external power sensor assembly (p/n 030 03547-xxx).  
Refer to your CalAmp sales channel for details.
 
The file names entered in this section should match the file names in your unit 
(Note: file names are case sensitive.)
 These files are needed to properly display 
the Forward and Reverse power values.  
 
6.8.10.1 
Calibration Files  
Special electrical sensors are used to measure the values of real world quantities such as forward or re-
verse  RF  power.  These  sensors  represent  all  measurements  in  Volts  and  require  a  conversion  to  proper 
units where applicable. This conversion is achieved by use of mathematical transfer functions, which also 
provide a way of calibrating the sensor hardware.  
The transfer function can be represented by a simple look-up table that approximates a continuous func-
tion  by  a  series  of  data  points.  Each  data  point  represents  an  {X
in
,  Y
out
}  pair,  where  X
in
  is  the  sensor’s 
output-a measurement in Volts, and Y
out
 is the corresponding value in a desired unit of measurement. Li-
near interpolation is used to generate Y
out
 values for any given X
in 
value in between the data points sup-
plied in the look-up table. 
The series of data points in a look-up table are listed in a text calibration file and is read by the Piecewise 
Linear  Interpolation  Calibrated  Conversion  (PWLICC)  software  module,  employed  in  Paragon4  radio 
base station to convert the sensor output into a desired value. 
CalAmp supplies look-up tables for forward and reverse power measurements. These tables contain a set 
of  values  in Volts  (X
in
)  with  their  corresponding  values  in  Watts  (Y
out
).  Similar look-up  tables  need  be 
created for user-supplied external analog devices connected to the base station’s backplane for diagnostics 
and monitoring if other than voltage measurement units are preferred.