Справочник Пользователя для TransCore 05531
Encompass 4/4800 Multiprotocol Reader System Guide
D-14
643NN
Set ATA operating range
NN = 00 (shortest) to 1F (longest)
1F = default
NN = 00 (shortest) to 1F (longest)
1F = default
Done
644NN**
Set attenuation**
NN = 00 to 0A
NN = 00 to 0A
Done
645NN**
Set Encompass 4/4800
Multiprotocol Reader operating
range**
Multiprotocol Reader operating
range**
NN = 00 (shortest) to 1F (longest)
Done
65
Reset power fail bit
Done
66F
Load default operating
parameters
parameters
Done or Error
67N
Set output pulse duration
N = 0–F
(4,8,12,16,20,24,32,40,48,
60,76,152,228,300,376, 752 ms)
N = 0–F
(4,8,12,16,20,24,32,40,48,
60,76,152,228,300,376, 752 ms)
Done or Error
67C
Set output pulse
duration = 228 ms
duration = 228 ms
Done or Error
6900
Disable presence
without tag reports
without tag reports
Done
6901
Enable presence without
tag reports
tag reports
Done
6920
Turn RF off on timeout
Done
6921
Turn RF off on timeout/tag
Done
6922
Turn RF off on
timeout/no presence
timeout/no presence
Done
693N
Set RF timeout
N = 0–F
(always expired, 4,8,12,20,24,
32,48,60,92,152, 300,452,
600,752, infinite)
N = 0–F
(always expired, 4,8,12,20,24,
32,48,60,92,152, 300,452,
600,752, infinite)
Done or Error
693F
Set RF timeout = infinite
Done
6940
Disable input inversion
Done
6941
Enable input inversion
Done
Table D-2 Encompass 4/4800 Multiprotocol Reader Commands Listed
Numerically (continued)
Numerically (continued)
Number
Command Name
Reader Message