O
PERATION
  
CHAPTER
 
3  
 
Page  6 
 
Short Range Programmer VRT—User Guide   
 
 
P/N 52806T100 Rev 1 April 2003  
  AMCO Automated Systems
 
 
BACK SPACE.  Moves the cursor (dark flashing box) back one position 
to allow the user to change the character displayed in the cursor’s 
position. 
 
LIGHT.  Alternately turns the display backlight on and off. Backlight uses 
battery power and should be turned off when not needed. 
 
MODE. Cycles through all SRP functional modes, advancing one mode 
per press of the button. 
 
LAST SN/WC. Toggles between the last successfully interrogated serial 
number
 (LAST SN) and wild card (WC). 
 
ENTER.
 Moves the cursor from one input field to the next on the 
displayed screen. 
 
INTERROGATE. Searches for and initiates communication with the 
selected transponder (if a serial number was entered) or the nearest 
transponder (if Wild Card is used). This button is also used to program 
the baseline meter reading, correction factor (V9 and VRT) and a  variety 
of other features (VRT) into transponders. 
 
 
SRP Modes 
 
The SRP has eight functional modes for a variety of operations. 
 
1.  Clock – 24 Hour Format Mode.  Allows the user to set the current 
time and date into the SRP.   
 
•  When interrogating any transponder the SRP may also 
broadcast its current time. If the SRP is in Broadcast Mode, all 
VRT transponders within range of the interrogation will reset their 
internal clocks to match the SRP time. 
 
2.  FIND SN/VERS/TYPE Mode.  Allows you to read and display the 
transponder’s serial number, type and firmware version. 
 
•  You can interrogate transponders either by using the Wild Card 
option (to search for any nearby transponders) or by entering a 
specific transponder serial number.  
 
•  Once the SRP has read the desired transponder, you are ready 
to perform other functions and switch to other modes as 
required.  
 
•  NOTE: Find is the only mode in which interrogation acquires 
transponder firmware version and type information needed for 
other operations.