AY-x6255 Family 
CSN SELECT Smart Card Readers 
Installation and User Manual 
1.
  Introduction 
The AY-x6255 is a family of multi-format contactless smart card 
readers for use in access control system solutions. 
CSN SELECT readers support reading from the secure memory of the 
following credential technologies: 
 
MIFARE Ultralight / Ultralight C 
 
MIFARE Classic 
 
MIFARE Plus S / Plus X 
 
MIFARE DESFire EV1 
 
ISO 14443A 
 
ISO 14443B 
 
ISO 15693 
 
iClass 
 
ISO 18092 (NFCIP-1) 
 
FeliCa 
1.1
 
Box Content 
Before beginning, verify that all of the following is in the box. If 
anything is missing, please report the discrepancy to your nearest 
Rosslare office. 
 
One AY-x6255 unit 
 
Installation kit – Includes two wall plugs, two mounting screws, 
security Torx screw, and security Torx screw tool 
 
Installation and operating instructions 
 
 
 
 
AY-K6255 
AY-L6255 
AY-H6255 
AY-M6255 
2.
  Technical Specifications 
2.1
 
Electrical Characteristics 
Power Supply Type 
Linear (recommended) 
Operating Voltage Range  8 to 16 VDC 
Current @ 12 V 
Standby: 100 mA 
Maximum: 120 mA 
Read Range* 
MIFARE Classic EV1: 40 to 45 mm (1.5 to 1.8 in.) 
MIFARE Plus: 30 mm (1.2 in.) 
MIFARE DESFire EV1: 30 mm (1.2 in.) 
LED Control Input 1** 
Green LED control, TTL 
LED Control Input 2** 
Red LED control, TTL 
Auxiliary Input** 
Buzzer control, TTL 
Auxiliary Output** 
Tamper output (open collector, active low, max. 
sink current 30 mA) 
Maximum Cable Distance 
to Controller 
Wiegand: 150 m (500 ft) with 18-AWG cable 
OSDP (RS-485): 1200 m (4,000 ft) with 2x2 18-
AWG twisted shielded cable 
*  Measured using a Rosslare MIFARE card cards. Range also depends on 
electrical environment and proximity to metal. 
** Standard configuration. Custom configurations are available
2.2
 
Environmental Characteristics 
Operating Temp. Range 
-25°C to 65°C (-13°F to 149°F) 
Operating Humidity Range 
0 to 95% (non-condensing) 
Outdoor Usage 
Weather-resistant, UV-resistant, meets IP65, 
epoxy-potted, suitable for indoor and outdoor 
use 
2.3
 
Physical Characteristics 
Dimensions 
(H x W x D) 
AY-K6255: 80.5 x 40.5 x 14.7 mm 
(3.2 x 1.6 x 0.6 in.) 
AY-L6255: 144.9 x 42.9 x 22.1 mm 
(5.7 x 1.7 x 0.9 in.) 
AY-H6255: 110.7 x 75.0 x 17.1 mm 
(4.4 x 3.0 x 0.7 in.) 
AY-M6255: 89.5 x 88.9 x 16.8 mm 
(3.5 x 3.5 x 0.7 in.) 
Weight 
AY-K6255: 77 g (2.7 oz) 
AY-L6255: 126 g (4.4 oz) 
AY-H6255: 163 g (5.7 oz) 
AY-M6255: 145 g (5.1 oz.) 
3.
  Wiring Instructions 
The units are supplied with a 10-conductor 18” (46-cm) pigtail or with 
10 terminal blocks. 
To connect a pigtail reader to the controller: 
1.
  Prepare the reader cable by cutting its jacket back 3.2 cm (1¼”) 
and strip the insulation from the wires 1.3 cm (½"). 
2.
  Prepare the controller cable by cutting its jacket back 3.2 cm (1¼") 
and strip the insulation from the wires 1.3 cm (½"). 
3.
  Splice the reader’s pigtail wires to the corresponding controller 
wires (as indicated in Table 1) and cover each joint with insulating 
tape. 
4.
  If the tamper output is being utilized, connect the purple wire to 
the correct input on the controller. 
The LED control may be configured by the factory to function 
either as a LED control or as buzzer control. Currently, the auxiliary 
input is used as buzzer control and LED Control 1 is used as the 
green LED control. 
5.
  Trim and cover all unused conductors. 
Table 1: AY-x6255 Wiring 
Wire Color 
Output 
Red 
Power 
Black 
Ground 
Green 
Data 0 / Data 
White 
Data 1 / Clock 
Purple 
Tamper Output 
Orange 
Green LED control 
Brown 
Red LED control 
Yellow 
Buzzer control / Auxiliary input 
Blue 
OSDP-RS-485-A* 
Gray 
OSDP-RS-485-B* 
*H and M models only 
 
 
  The individual wires from the reader are color coded according the 
Wiegand standard. 
  When using a separate power supply for the reader, this supply and 
that of the controller must have a common ground. 
  The reader’s cable shield wire should be preferably attached to an earth 
ground, or a signal ground connection at the panel, or power supply 
end of the cable.