Справочник Пользователя для INNCOM International Inc. 01-9437

Скачать
Страница из 10
INNCOM B574 Datasheet
   
P a g e
 | 9 
 
 
Ordering Notes 
B574  
B574 is the Layer-2 mesh network controller. This configuration is used in Layer-2 applications 
only. This configuration will never require the IR5 option but is typically ordered with a 20dB TXR 
radio as the wireless communications option. This product can be powered from the PoE or 12VDC 
SMPS. Ensure that the B574 shelf software is specified when ordering in this configuration. 
PC‐803 
[Note: Currently, there is no software application available for this configuration]
 
The PC-803 (protocol converter) is the room gateway configuration of the product. In this 
configuration, the product converts in-room IR, RF (Layer-1), or S5bus traffic to Ethernet towards 
the server. The PC-803 mirrors the TCT in functionality with the addition of Layer-1 capability. 
Order this product with a 0dB TXR radio unless otherwise specified. The radio and IR5 module are 
mutually exclusive; they cannot be used simultaneously in the same unit (but the PC-803 can 
accommodate an external IR5 Eye). Ensure that the PC-803 shelf software is specified when 
ordering in this configuration. 
Examples: 
01-9437.B574.P12.RF2.A0: A B574 supplied with an external power supply (04-4040), 
populated with a 20dB Radio (02-9894), and no IR5 eye. This is a typical configuration for the 
B574. 
01-9437.PC-803.POE.RF0.A0: A PC-803 supplied with the PoE module for power (02-9949), 0db 
Radio (02-9994). 
Sub‐assemblies: 
Part Name 
Description 
Part Number 
B574/PC-803 logic board 
Logic board 
02-9845 
PoE 
Power over Ethernet Module 
02-9949 
12VDC SMPS 
External 12VDC Power Supply  
04-4040 
0 dB Radio 
0db RF TXR radio module 
02-9994 
20 dB Radio  
20dB RF TXR radio module 
02-9894 
IR5 Eye 
IR5 Eye 
02-9467 
PSH1-L12 
Power supply module (logic board) 
02-4052 
References 
Title 
Location 
B574 Engineering Manual 
T:\Library\INNCOM Products\Devices\B574-(TCT.RF)\B574 Engineering Manual, v1.0 
EM.pdf 
B573 Users Guide 
T:\Library\INNCOM Products\Systems\IWAN_Reference\Docu\B573_MC Users 
Guide.pdf 
Document Revision History 
Revision 
Date Issued 
 Reason 
0.1 
12-Jun-2009 
FCC for B574 
0.2 
24-Jun-2009 
Edited for sense and format 
0.3 
29-Jun-2009 
Incorporated review comments 
0.4 
08-Jul-2009 
Clarified network bridge language and capacity 
0.5 
22-Jul-2009 
Incorporated final R&D review comments 
1.0 
03-Aug-2009 
Incorporated Approvers’ comments and released.