Справочник Пользователя для Climax Technology Co Ltd DC23

Скачать
Страница из 4
 
3
 
If the Control Panel has not received the signal from the Door Contact for a preset period time, the Control Panel will 
indicate the particular Door Contact is experiencing an out-of-signal problem. 
 
Test Mode 
 
Under Normal Mode, press the Test Button to transmit a test signal and learning code to the Control Panel. The Door 
Contact will also enter the Test Mode for 3 minutes.   
 
Under Test Mode, the LED will light up whenever the Door Contact is activated.
 
 
 
Each additional Test Button press will reset Test Mode time to 3 minutes. 
 
Getting Started 
 
Open the cover of the Door Contact and insert the battery. 
 
Put the Control Panel into Learning Mode (please refer to panel operation manual). 
 
Press the Door Contact test button. 
 
Refer to your Control Panel operation manual to complete the learn-in process. 
 
After  the  Door  Contact  is  learned-in,  place  the  Control  Panel  into  (Walk  Test)  mode,  hold  the  Door  Contact  in  the 
desired location, and press the Test button to transmit test signal to Control Panel. If the Control Panel is within Door 
Contact signal range, the panel will display door contact information accordingly.   
 
Proceed with mounting and installation once you are satisfied that the Door Contact location functions properly. 
 
Installation 
  Installation Guideline 
 
The Door Contact should be installed on the door/window frame, and the magnet on the door/window 
 
The distance between the Door Contact and the magnet should be no more than 15mm when the door is closed. 
 
Avoid mounting the Door Contact on metallic surface. If mounting on metallic surface, make sure to test whether the 
Door Contact can be triggered when the door is opened. 
 
Mount the Door Contact as high as possible. 
 
Mounting the Door Contact 
1. Find a suitable location close to your door/window to install the Door Contact. 
2. The Door Contact has 2 rib-marks on one side (refer to figure), marking the internal magnet switch location. The door 
contact should be installed either upright or inverted to ensure that the rib-marked side faces the magnet. 
3. To mount the Door Contact: 
a)  Use the 2 Door Contact mounting holes as a template for appropriate hole positioning. 
b)     Use the provided wall plugs for plaster/brick installation.   
c)  Screw the Door Contact into the provided wall plugs. 
4. Fit the magnet on the door using the small piece of double sided adhesive tape or with provided screws. The magnet 
must align with the rib-mark side of the Door Contact as shown in figure. Installation is now complete. 
 
 
 
 
 
 
 
FCC Statement