Справочник Пользователя для Climax Technology Co Ltd TMSTZB

Скачать
Страница из 7
 
2
7. Away Button 
Press the button to change Thermostat to Away Mode. 
8. Wall Mounting Holes 
9. Back Cover Latch 
Press both latches on the back cover to remove cover if needed. 
10. Wiring Connection Terminals 
 
Name 
Description 
Name 
Description 
Cooling 
RH 
24VAC Power Input   
Heating 
 
 
Fan 
 
 
OB 
Reversing Valve 
 
 
Refer to Wiring Diagram below for detail. 
Wiring of the Thermostat should be performed by a certified technician with proper equipment 
to ensure safety 
 
11. Battery Compartment 
Insert 2 AA Alkaline batteries to power on the Thermostat. 
 
Features 
  Battery and Low Battery Detection 
The Thermostat uses 2 AA Alkaline batteries as its power source. The Thermostat features Low 
Battery  Detection  function.  When  the  battery  voltage  is  low,  the  Thermostat  will  transmit  Low 
Battery signal to the coordinator in ZigBee network. The Low Battery LED will also begin to flash to 
indicate the condition. 
  Manual Operation 
   
 
Mode and Temperature Setting:
 
Cool, Heat and Auto Mode
 
 
Press  any  of  the  UP,  Down  or  Mode  button,  the  Thermostat  will  display  current  mode, 
temperature set point and light up LCD backlight for 4 seconds.
 
 
Press the Mode button again during this period to set Thermostat mode between Cool, Heat 
and Auto.
 
Press the Up or Down button to select temperature set point. 
Heat setpoint range: 9˚C ~ 30˚C. 
Cool setpoint range: 11˚C ~ 32˚C.   
When under Auto mode,  you  will first select Auto Cool set point and pressing UP  or Down 
button, press Mode button again to select to Auto Heat set point. The Cool set point must be 
at least 2℃  higher then Heat set point. 
 
Press  the  Mode  button  The Thermostat  will  exit  setting  screen  and  apply  the  new  setting 
after 4 seconds of inactivity.