2
7. Away Button
Press the button to change Thermostat to Away Mode.
8. Wall Mounting Holes
9. Back Cover Latch
9. Back Cover Latch
Press both latches on the back cover to remove cover if needed.
10. Wiring Connection Terminals
Name
Description
Name
Description
Y
Cooling
RH
24VAC Power Input
W
Heating
G
Fan
OB
Reversing Valve
Refer to Wiring Diagram below for detail.
Wiring of the Thermostat should be performed by a certified technician with proper equipment
to ensure safety
Wiring of the Thermostat should be performed by a certified technician with proper equipment
to ensure safety
11. Battery Compartment
Insert 2 AA Alkaline batteries to power on the Thermostat.
Features
Battery and Low Battery Detection
The Thermostat uses 2 AA Alkaline batteries as its power source. The Thermostat features Low
Battery Detection function. When the battery voltage is low, the Thermostat will transmit Low
Battery signal to the coordinator in ZigBee network. The Low Battery LED will also begin to flash to
indicate the condition.
Battery Detection function. When the battery voltage is low, the Thermostat will transmit Low
Battery signal to the coordinator in ZigBee network. The Low Battery LED will also begin to flash to
indicate the condition.
Manual Operation
Mode and Temperature Setting:
Cool, Heat and Auto Mode
Press any of the UP, Down or Mode button, the Thermostat will display current mode,
temperature set point and light up LCD backlight for 4 seconds.
temperature set point and light up LCD backlight for 4 seconds.
Press the Mode button again during this period to set Thermostat mode between Cool, Heat
and Auto.
and Auto.
Press the Up or Down button to select temperature set point.
Heat setpoint range: 9˚C ~ 30˚C.
Cool setpoint range: 11˚C ~ 32˚C.
When under Auto mode, you will first select Auto Cool set point and pressing UP or Down
button, press Mode button again to select to Auto Heat set point. The Cool set point must be
at least 2℃ higher then Heat set point.
Heat setpoint range: 9˚C ~ 30˚C.
Cool setpoint range: 11˚C ~ 32˚C.
When under Auto mode, you will first select Auto Cool set point and pressing UP or Down
button, press Mode button again to select to Auto Heat set point. The Cool set point must be
at least 2℃ higher then Heat set point.
Press the Mode button The Thermostat will exit setting screen and apply the new setting
after 4 seconds of inactivity.