WARNING: Disconnect primary power prior to servicing.
Section 2 Operation
Maxiva ULX ATSC Series
User Manual
User Manual
Figure 2-20 System Setup Screen
NOTE:
The Save Setup button allows storage of up to eight setups for the purpose of
N+1 operation. All the calibrations for the transmitter are saved in the MCM
module. This means the transmitter can change to anyone of 8 channels and be
fully calibrated by simply recalling the set up entry. The N+1 controller will send
the set up the entry that needs to be recalled, as well as set the exciter frequency.
N+1 operation. All the calibrations for the transmitter are saved in the MCM
module. This means the transmitter can change to anyone of 8 channels and be
fully calibrated by simply recalling the set up entry. The N+1 controller will send
the set up the entry that needs to be recalled, as well as set the exciter frequency.
2.9.3.3
Cabinet Setup
•
Cab Pwr Out (W): Set cabinet output power here. This is the power out of the cabi-
net before the combiner or filter. This needs to be set for each cabinet. Sets cabinet
nominal power used to set ALC level. Maximum cabinet power is limited to 10%
over this value.
nominal power used to set ALC level. Maximum cabinet power is limited to 10%
over this value.
•
Number of PA’s: Enter the number of PA modules in the selected cabinet. This needs
to be set for each cabinet.
•
Number of IPA’s: Enter the number of IPA modules in the selected cabinet. This
needs to be set for each cabinet.
•
Cooling Pumps: Set this to either 1 or 2 depending on how many pumps are in pump
module/heat exchanger for this cabinet. This needs to be set for each cabinet.