Справочник Пользователя для Tait International Limited TBCK4A
TB9400 Installation and Operation Manual
Troubleshooting
105
© Tait Limited March 2015
7
Troubleshooting
Check that all front and rear connectors and cables are in place, and that
power switches are on. If problems persist, contact your regional Tait
office.
power switches are on. If problems persist, contact your regional Tait
office.
Symptom
Possible Cause
Action
Alarm LED red and steady
(not flashing)
(not flashing)
The base station is in
Offline mode
Offline mode
Use the web interface to put the base station in
Online mode
Online mode
Alarm LED flashing
One or more faults are
present
present
Use the web interface to identify the faulty module
Alarm LED flashing,
display shows “Please
wait...”, fans are running
slowly
display shows “Please
wait...”, fans are running
slowly
Front panel has lost
communication with
reciter 1
communication with
reciter 1
Check cable connections. Check front panel
D-range connector. Use the web interface to
check reciter 1.
D-range connector. Use the web interface to
check reciter 1.
Power LED on front panel
is on, but keypad does not
work
is on, but keypad does not
work
Keypad is disabled
Check that the keypad is enabled in the web
interface (Configure > Base Station >
Miscellaneous)
interface (Configure > Base Station >
Miscellaneous)
Power LED flashing, fans
are running, but display is
blank
are running, but display is
blank
The base station is
downloading firmware
downloading firmware
Use the web interface to monitor the progress of
the firmware download
the firmware download
No power or LEDs on
front panel
front panel
System control bus not
connected to front panel
connected to front panel
Check cable connections
Pins bent on 15-pin
D-range plug on front
panel
D-range plug on front
panel
Replace or repair D-range plug
Desired feature is not
operating
operating
Feature license missing
Check that you have the necessary feature
licenses (refer to
licenses (refer to
and the
Help)
Feature license present
but feature is not enabled
but feature is not enabled
Use the web interface to enable the feature
Tx stuck on
Tx and Rx frequencies are
the same
the same
Reconfigure Tx and Rx with different frequencies
The base station appears
to make random
transmissions
to make random
transmissions
CWID feature enabled
No action: CWID transmissions are made
according to configuration settings
according to configuration settings
PA has low power
Channel is configured to
low power
low power
Use the web interface to check the power settings
PA may have suffered
partial damage
partial damage
Replace module and send faulty module for
servicing
servicing