Front Panel Fans
The front panel is equipped with three fans. One fan is for the PMU and the
other two are for the reciter/PA pairs in a 50W base station, or for the PA
and reciter in a 100W base station. Front panel fans do not operate
continuously, but are switched on and off as needed. The PMU and PA
control their own fan. Reciters request the front panel to turn on their fan.
The reciter in slot 1can also carry out a fan test on all three fans.
other two are for the reciter/PA pairs in a 50W base station, or for the PA
and reciter in a 100W base station. Front panel fans do not operate
continuously, but are switched on and off as needed. The PMU and PA
control their own fan. Reciters request the front panel to turn on their fan.
The reciter in slot 1can also carry out a fan test on all three fans.
Front panel fans are 3-wire fans (power, ground, and rotation detect). The
reciter can monitor whether the fans are rotating and generate an alarm if
the fan fails.
reciter can monitor whether the fans are rotating and generate an alarm if
the fan fails.
The fans turn on for a few seconds when the base station is powered up, and
also after the front panel is refitted to a base station which is powered up.
also after the front panel is refitted to a base station which is powered up.
Configuring Fan
Control
The operation of the PA fan is configurable via the web interface; you can
specify the threshold temperature at which the fan will be turned on, and
set the fan to operate only when the PA is transmitting.
specify the threshold temperature at which the fan will be turned on, and
set the fan to operate only when the PA is transmitting.
The PMU fan has fixed on/off thresholds and a defined set of duty cycles
based on the PMU temperature and load current, as described in the
following table.
based on the PMU temperature and load current, as described in the
following table.
PMU Temperature
Current
Fan Duty Cycle
<149°F (65°C)
<4A
4A–6A
6A–8A
8A–12A
12A–14A
≥15A
4A–6A
6A–8A
8A–12A
12A–14A
≥15A
always off
2 minutes on, 8 minutes off
2 minutes on, 5 minutes off
3 minutes on, 3 minutes off
4 minutes on, 1 minute off
always on
2 minutes on, 8 minutes off
2 minutes on, 5 minutes off
3 minutes on, 3 minutes off
4 minutes on, 1 minute off
always on
>149°F (65°C)
––
always on