Справочник Пользователя для Tait International Limited TBCK4A

Скачать
Страница из 144
 
TB9400 Installation and Operation Manual
Operation
49
© Tait Limited March 2015
3.2.3
PMU
The only controls on the PMU are the on/off switches on the rear panel for 
the AC and DC modules, and the indicator LEDs visible through a slot in 
its front panel.
Warning
The AC and DC module on/off switches do not totally 
isolate the internal circuitry of the PMU from the AC or DC power 
supplies. You must disconnect the AC and DC supplies from the 
PMU before dismantling or carrying out any maintenance. Refer to 
the service manual for the correct servicing procedures.
AC Module On/Off 
Switch
This switch turns the AC input to the PMU on and off. Note that this switch 
breaks only the phase circuit, not the neutral.
The red button remains “out” whether on or off.
DC Module On/Off 
Switch
This switch turns the DC output from the PMU on and off. Note that this 
switch does not disconnect power from the DC converter itself. It disables 
the converter by switching off its control circuitry. Even when the DC 
converter is off, the DC input is still connected to its power circuitry. 
The switch is recessed to prevent the DC module being accidentally 
switched off. 
Figure 3.5
Operating controls on the PMU
b
AC module on/off switch
d
indicator LEDs
c
DC module on/off switch
b
c
rear view
d
front view