TB9400 Installation and Operation Manual
Installation
97
© Tait Limited March 2015
5.6.3
Connecting DC Power
The PMU is designed to accept a nominal 12VDC, 24VDC or 48VDC 
input (depending on the model) with negative or positive ground. There is 
a minimum DC startup threshold to prevent damaging a battery which has 
little capacity left.
You must connect the DC supply from the battery to the PMU via a fuse or 
DC-rated circuit breaker with the appropriate rating, as shown in the table 
below. The circuit breaker must have a contact separation of 3mm, an 
interrupt capacity of 1000A or more, and an inrush current capability of at 
least 500A for a minimum of 3.5ms. 
Notice The inrush current is not affected by the state of the DC mod-
ule on/off switch on the PMU. This switch does not disconnect power 
from the DC converter itself. It disables the converter by switching off 
its control circuitry. Even when the DC converter is off, the DC input is 
still connected to its power circuitry. 
The DC input leads should be of a suitable gauge to ensure less than 0.2V 
drop at maximum load over the required length of lead.
Terminate and insulate the DC input leads to protect them from 
accidentally shorting to the subrack if the PMU is removed before the leads 
are disconnected. Protective covers for the DC terminals are supplied with 
each PMU. We recommend a screw torque of 18–20lbf·in (2–2.25N·m). 
Nominal Supply 
Voltage
Input Voltage 
Range
Circuit Breaker/
Fuse Rating
a
a. The actual current consumption of the base station will be lower than these re-
quirements (refer to the Specifications Manual for more information).
Recommended 
Wire Gauge
b
b. For a length of 5ft to 6.5ft (1.5m to 2m) (typical).
12VDC
10VDC to 16.8VDC 60A
2AWG / 35mm
2
24VDC
20VDC to 33.6VDC 30A
5AWG / 16mm
2
48VDC
40VDC to 60VDC
15A
8AWG / 8mm
2